background image

 

1-4

Cisco MSE 3365 Installation Guide

Chapter 1      Overview

  Status LEDs and Buttons

Figure 1-3

Front Panel LEDs 

 

1

Hard drive fault LED

6

Fan status LED

2

Hard drive activity LED

7

Temperature status LED

3

Power button/power status LED

8

Power supply status LED

4

Identification button/LED

9

Network link activity LED

5

System status LED

Table 1-1

Front Panel LEDs, Definitions of States

LED Name

State

1

Hard drive fault

Off—The hard drive is operating properly.

Amber—Drive fault detected.

Amber, blinking—The device is rebuilding.

Amber, blinking with one-second interval—Drive locate function activated.

2

Hard drive activity 

Off—There is no hard drive in the hard drive tray (no access, no fault).

Green—The hard drive is ready.

Green, blinking—The hard drive is reading or writing data.

3

Power button/LED

Off—There is no AC power to the Cisco MSE 3365.

Amber—Cisco MSE 3365 is in standby power mode. Power is supplied only to the 
Cisco IMC and some motherboard functions.

Green—Cisco MSE 3365 is in main power mode. Power is supplied to all the MSE 
3365 components. 

4

Unit identification

Off—The unit identification function is not in use.

Blue—The unit identification function is activated.

353088

9

7

5

3

4

6

8

BAY 02

BAY 01

BAY 03

BAY 04

BAY 05

BAY 06

BAY 08

BAY 07

2

1

Содержание MSE 3365

Страница 1: ... Mobility Services Engine MSE Details on running the automatic installation script is also provided This chapter contains the following sections External Features Overview page 1 1 Status LEDs and Buttons page 1 3 General Warnings Regulatory and Safety page 1 8 External Features Overview The Cisco MSE 3365 comes with four Small form factor SFF drives See Figure 1 1 ...

Страница 2: ...support SAS SATA and NVMe PCIe solid state drives SSDs 8 Fan status LED 3 Pull out asset tag 9 Temperature status LED 4 Operations panel buttons and LEDs 10 Power supply status LED 5 Power button power status LED 11 Network link activity LED 6 Unit identification button LED 12 KVM connector used with KVM cable that provides two USB 2 0 one VGA and one serial connector 11 9 7 5 6 8 10 352973 HDD 02...

Страница 3: ...1 1 defines the LED states 1 PCIe riser 1 slot 1 not used 7 Serial port RJ 45 connector 2 PCIe riser 2 slot 2 not used 8 Dual 1 Gb Ethernet ports LAN1 and LAN2 Port 1 is normally used by the Cisco MSE eth0 for communication with the Cisco Wireless LAN Controllers and Cisco Prime Infrastructure 3 Modular LAN on motherboard mLOM card slot not used 9 VGA video port DB 15 4 Grounding lug hole for DC p...

Страница 4: ...mber blinking with one second interval Drive locate function activated 2 Hard drive activity Off There is no hard drive in the hard drive tray no access no fault Green The hard drive is ready Green blinking The hard drive is reading or writing data 3 Power button LED Off There is no AC power to the Cisco MSE 3365 Amber Cisco MSE 3365 is in standby power mode Power is supplied only to the Cisco IMC...

Страница 5: ... properly Amber steady One or more fan modules breached the critical threshold Amber blinking One or more fan modules breached the non recoverable threshold 7 Temperature status Green Cisco MSE 3365 is operating at normal temperature Amber steady One or more temperature sensors breached the critical threshold Amber blinking One or more temperature sensors breached the non recoverable threshold 8 P...

Страница 6: ...ower supply status LED 4 1 Gb Ethernet link speed LED Table 1 2 Rear Panel LEDs Definitions of States LED Name State 2 1 Gb Ethernet dedicated management link speed Off Link speed is 10 Mbps Amber Link speed is 100 Mbps Green Link speed is 1 Gbps 3 1 Gb Ethernet dedicated management link status Off No link is present Green Link is active Green blinking Traffic is present on the active link 4 1 Gb ...

Страница 7: ...ated 7 Power supply status AC power supplies Off No AC input 12 V main power off 12 V standby power off Green blinking 12 V main power off 12 V standby power on Green solid 12 V main power on 12 V standby power on Amber blinking Warning detected but 12 V main power on Amber solid Critical error detected 12 V main power off Table 1 2 Rear Panel LEDs Definitions of States continued LED Name State ...

Страница 8: ...n equipment damage or loss of data Warnings The warnings below are general warnings that are applicable to the entire guide Specific warnings are included in the sections to which they apply Warning There is the danger of explosion if the battery is replaced incorrectly Replace the battery only with the same or equivalent type recommended by the manufacturer Dispose of used batteries according to ...

Страница 9: ...General Warnings Regulatory and Safety Regulatory and Safety Note Refer to Appendix A for translated safety information for the Cisco 3365 Mobility Services Engine Note Refer to Appendix B for regulatory information for the Cisco 3365 Mobility Services Engine ...

Страница 10: ...1 10 Cisco MSE 3365 Installation Guide Chapter 1 Overview General Warnings Regulatory and Safety ...