Chapter 3 Installing the Cisco 12404 Internet Router
Connecting to an AC Power Source
3-29
Cisco 12404 Internet Router Installation and Configuration Guide
OL-11636-01
Figure 3-17
AC PEM
•
All electrical connections between the power supply and the backplane are
made automatically when the power supply is fully inserted in the power
supply bay.
Step 4
Locate the AC power cord and remove it from its shipping packaging. Verify that
the AC power cord shipped with the power supply is the correct type for your site.
Note
If you have an incorrect type of power cord, contact your service
representative for a replacement.
Step 5
Plug the AC power cord into the AC PEM.
Step 6
Connect the other end of the AC power cord to the AC power source outlet.
Note
We recommend attaching each AC PEM to an independent power source
for full redundancy. We also recommend that you use an uninterruptable
power source (UPS) to protect against power failures at your site.
1
AC PEM handle
4
Power cord receptacle
2
On/Off switch
5
LEDs
3
Bail Latch
6
Captive screws
INPUT
OK
OUTPUT
FAIL
INPUT
100-240V
12A
50/80HZ
OUTPUT
OK
66289
4
5
6
1
2
3
todd.book Page 29 Tuesday, November 27, 2007 6:02 PM