B-59
Cisco IE 3000 Switch Hardware Installation Guide
Appendix B Installation In a Hazardous Environment
Connecting the Switch to the Power Converter
Connecting the Power Converter to a DC Power Source
You can also connect the power converter to a DC power source. The power converter adapts the power
source voltage to the 24 VDC that the switch requires.
Follow these steps to connect the power converter to a DC power source.
Note
Use copper conductors only, rated at a minimum temperature of 167°F (75°C).
Warning
Use twisted-pair supply wires suitable for 86°F (30°C) above surrounding ambient temperature
outside the enclosure. Statement 1067
Step 1
Measure a single length of stranded copper wire long enough to connect the power converter to the earth
ground. The wire color might differ depending on the country that you are using it in.
For connections from the power converter to earth ground, use shielded 18-AWG stranded copper wire,
such as Belden part number 9912 or the equivalent.
Step 2
Measure a length of twisted-pair copper wire long enough to connect the power converter to the DC
power source.
For DC connections from the power converter to the DC source, use 18-AWG twisted-pair copper wire,
such as Belden part number 9344 or the equivalent.
Step 3
Using a 18-gauge wire-stripping tool, strip the ground wire and both ends of the twisted pair wires to
0.25 inch (6.3 mm) ± 0.02 inch (0.5 mm). Do not strip more than 0.27 inch (6.8 mm) of insulation from
the wires. Stripping more than the recommended amount of wire can leave exposed wire from the power
and relay connector after installation. See
.
Step 4
Connect one end of the stranded copper wire to a grounded bare metal surface, such as a ground bus, a
grounded DIN rail, or a grounded bare rack.
Step 5
Insert the other end of the exposed ground wire lead into the earth-ground wire connection on the power
converter terminal block. Only wire
with
insulation
should extend from the connection. See
Step 6
Tighten the earth-ground wire connection terminal block screw.
Note
The torque should not exceed 2.2 in-lb (0.25 Nm).
Содержание IE 3000
Страница 34: ...1 24 Cisco IE 3000 Switch Hardware Installation Guide Chapter 1 Overview Network Configurations ...
Страница 102: ...3 8 Cisco IE 3000 Switch Hardware Installation Guide Chapter 3 Troubleshooting Finding the Switch Serial Number ...
Страница 182: ...C 12 Cisco IE 3000 Switch Hardware Installation Guide Appendix C Cable and Connectors Cable and Adapter Specifications ...