Fluidmesh radio devices that are capable of operating as part of a mesh
network, including the Cisco FM3500 Endo, are shipped from the factory
in
Mesh Point
mode.
All Fluidmesh radio transceiver devices are shipped with IP address
192.168.0.10
, and Netmask
255.255.255.0
.
The Cisco FM3500 Endo can be configured by using:
• The RACER™ Radio Configuration interface, or
• The on-board Configurator interface.
The difference between these interfaces is as follows:
FM Racer
is a centralized, internet-based configuration software platform
that is accessed from the Fluidmesh Partner Portal.
• An internet connection must be made between the Fluidmesh device
and the FM Racer Cloud Server (an internet-based radio
management service).
• Devices can be configured on an
Online
basis only: configuration
settings are applied to one or more devices without the need for a
configuration (*.CONF) file, and manual configuration is disabled.
• If devices must be configured on an
Offline
basis (in other words, if
the device is not connected to the internet, and therefore cannot
access its configuration settings from the FM Racer Cloud Server),
a separate configuration file can be uploaded to the device using
the Configurator (described below).
The
Configurator
is a localized configuration software platform that resides
on the Fluidmesh device.
• Local configuration is done by connecting a computer to the device
through a direct hardware connection, or through the internet.
• Using the Configurator, devices can be configured on an
Offline
basis
only. A configuration (*.CONF) file can be manually applied to set the
device parameters, or each device parameter can be manually set
by the device user.
• Offline configuration settings for more than one Fluidmesh device
type can be integrated into a single configuration file. When the
configuration file is uploaded to each device, the device automatically
loads the correct configuration settings for its device type.
To configure the unit using
FM Racer
, refer to the
Fluidmesh Networks
FM Racer User Manual
.
To configure the unit using the
Configurator
, refer to the following sub-
sections.