![Cisco FM3500 Endo Скачать руководство пользователя страница 38](http://html.mh-extra.com/html/cisco/fm3500-endo/fm3500-endo_installation-and-configuration-manual_67773038.webp)
Hardware installation
© 2021 Cisco and/or its affiliates. All rights reserved.
Page 38 of 177
5.2.3. Connecting the antennas to the Cisco FM3500 Endo
RPSMA antenna connections
Radio antennas are connected to the Cisco FM3500 Endo using reverse-
polarity sub-miniature version A (RPSMA) connectors.
Fluidmesh uses copper-tin-zinc-plated female RPSMA connectors. These
connectors are capable of corrosion resistance that exceeds the demands
imposed by
salt spray testing. The connectors are virtually
immune to corrosion, provided that they do not remain in contact with
standing salt water for long periods of time.
In the opinion of Fluidmesh engineers, certain brands of RPSMA plug
have shown outstanding performance. We can confidently recommend the
following brands:
•
Amphenol
•
Huber+Suhner
•
Rosenberger
•
Radiall
IMPORTANT
The FM3500 Endo is ingress-protection rated to standards
specified by EN 50155 and EN 45545.
To ensure the FM3500 Endo remains waterproof and
dustproof, follow all instructions in this section.
Following the instructions in this section will also ensure that the
FM3500 Endo is well prepared for any ingress-protection
testing.
WARNING
Before activating the unit, make sure that all RF feeds are
securely connected to an appropriate antenna. Never activate
any transceiver unit that is not connected to an antenna.
CAUTION
Do not remove the protective rubber sleeve (
from any female RPSMA plug if an antenna will not be
connected to the plug. Unprotected RPSMA contacts that are
exposed to water will oxidize, causing degraded performance.