is
fluidmesh
. To show the password as it is being typed, check
the
Show SNMP v3 password:
check-box.
4.
Choose the correct authentication protocol from the
SNMP v3
authentication proto:
drop-down. The available options are
MD5
and
SHA
.
IMPORTANT
The same SNMP authentication protocol must be set
for all Fluidmesh units in the wireless network.
5.
If needed, choose the correct encryption protocol from the
SNMP
v3 encryption:
drop-down. The available options are
No
Encryption
,
DES
(Data Encryption Standard) and
AES
(Advanced Encryption Standard).
IMPORTANT
The same encryption protocol must be set for all
Fluidmesh units in the wireless network.
6.
To change the current encryption passphrase, enter a new
passphrase in the
SNMP v3 encryption passphrase:
field. The
default encryption passphrase is
fluidmesh
. To show the
passphrase as it is being typed, check the
Show SNMP v3
encryption passphrase:
check-box.
7.
SNMP traps can be enabled for significant system-related events.
If needed, enable SNMP event traps by checking the
Enable
SNMP event trap:
check-box, and enter the name of the network
management station (NMS) host in the
NMS hostname:
field.
IMPORTANT
The NMS host to which traps are sent must have an
SNMP agent configured to collect v2c traps.
8.
You can also configure the unit to send SNMP traps at defined
periodic intervals. If needed, enable periodic SNMP traps by
checking the
Enable SNMP periodic trap:
check-box, and enter
the name of the network management station (NMS) host in the
NMS hostname:
field.
9.
Save the SNMP settings by clicking the
Save
button.
Alternatively, clear the settings by clicking the
Reset
button.
6.7.6. RADIUS configuration
The
RADIUS
window contains the controls to provide centralized
authentication, authorization, and accounting management using the
remote authentication dial-in user service (RADIUS) networking protocol.
Device configuration using the configurator interface
© 2021 Cisco and/or its affiliates. All rights reserved.
Page 80 of 138