10. Electrical power requirements
The following table describes:
• The electrical power requirements for each Fluidmesh hardware
device type.
• Which Fluidmesh hardware devices are capable of receiving power
through an IEEE 802.3 Ethernet port (whether from a power-
supplying device like a compatible network switch, or from a power-
over-Ethernet (PoE) injector), or through a DC IN power supply
port, or both.
• The specific voltage-variation tolerances of each Fluidmesh radio
transceiver unit type.
Table 8. Individual power requirements (FM1000 Gateway and
FM10000 Gateway)
Required input
power
FM1000
Gateway
(model
FM1000-
GWY)
FM10000
Gateway
(model
FM10000-
GWY)
DC IN
12 Vdc (from mains
AC power adapter
producing a
minimum of 60W
(12V/5A)).
X
First-generation FM10000
Gateway Gateway: unit may
be equipped with single
250W non-redundant AC
power supply unit (input
power: 100 Vac to 240 Vac at
50 Hz to 60 Hz).
X
Table 9. Individual power requirements (FM Ponte kit to FM4200
Mobi)
FM Ponte kit
(model
FMPONTE-50)
FM1200
Volo
(model
FM1200V-
HW)
FM1300
Otto
(model
FM1300T-
HW)
FM3200
Base
(model
FM3200)
FM3200
Endo
(model
FM3200E-
HW)
FM4200
Mobi
(model
FM4200)
PoE
24V
passive
PoE
X
X
48V
passive
PoE
X
X
X
Electrical power requirements
© 2021 Cisco and/or its affiliates. All rights reserved.