17-16
Cisco TelePresence System TX9000 and TX9200 Assembly, Use & Care, and Field-Replaceable Unit Guide
OL-27038-01
Chapter 17 Field-Replaceable Unit Guide
Replacing a Codec—Part Number CTS-CODEC-PRI-G2R= or CTS-CODEC-PRI-RCH= (PRC)
e.
Delete the MAC address of the previous codec from the Cisco Unified CM application user profile
that is used in Cisco TelePresence Manager (CTS-Manager).
f.
Add the new codec to the application user profile and click Save.
Step 6
Power on the system by turning the power switch on the four PDUs to the “ON” position.
Step 7
In a supported Internet browser, type in the IP address of for your TX9000 or TX9200 system.
Note
If your system is configured to use a static IP address instead of DHCP, see the
or TX9200 System That Uses a Static Network Address” section on page 15-5
Step 8
Enter the required information at the login screen.
The Cisco TelePresence Administrator window appears.
Step 9
Verify that the status of the Cisco Unified Communications Manager (seen in the lower left portion of
the window) is
Enabled/Up
.
Step 10
Make sure that the new codec is running Cisco TelePresence Administration Software version 1.9.0 or
later.
Note
The replacement codec might come pre-loaded with version 1.7.1.1 software. In this case, you cannot
immediately load the newest version of CTS software and need to perform an interim upgrade to 1.7.4.
For more information, see the “
Upgrading the CTS Software for Systems That Are Running Cisco
TelePresence Software Versions Prior to 1.7.4.
” section of
Installing and Configuring the Cisco
TelePresence Touch 12
.
Step 11
Navigate to
Troubleshooting > Hardware Setup
to verify that the cameras, displays, speakers, and
microphones are working properly.
Step 12
Select the correct table type, size, and distance by completing the following steps:
a.
Navigate to
Troubleshooting > Hardware Setup > Table Configuration
.
b.
Click
Start
to display the Table Configuration options.
c.
Under Table Shape, select the correct table shape.
d.
Under Table Size, select the correct table size.
e.
Under Table Distance, select the correct distance between the bezel of the system and the rear edge
of the table
Step 13
Perform the Auto Adjust camera setup procedure. This sets the white balance to the correct levels. See
the
for detailed instructions.
Step 14
Close bottom facade panels.
Upgrading CTS Software on a Secondary Codec
All codecs for a TX9000 ship with release 1.9.0 of the CTS software. If you must get a field-replaceable
unit for a codec, the new codec should be shipped to you with release 1.9.0 already installed. In the
highly unlikely event that the new codec ships with a pre-1.9.0 release, the software must be upgraded
to at least release 1.9.0.