Power-Supply Module Specifications
Dimensions
Weight
PSU Module
1.58 x 7 x 5 in. (4 x 17.8 x 12.7 cm)
(without mounting flanges)
2.55 lb (1.15 kg)
PWR-RGD-AC-DC-H
2.5 lb (1.13 kg)
PWR-RGD-LOW-DC-H
1.58 x 7x 6.18 in. (4 x 17.8 x 15.7
cm) (with mounting flanges)
3.2 lb (1.45 kg)
PWR-RGD-LOW-DC-250
N/A
.8 lbs
Blank cover
Alarm Ratings
Description
Specification
Senses an external dry contact. The open circuit voltage between
any alarm input (1 to 4) and alarm input common is 3.3 VDC. The
loop current is 3 mA max per input.
Do not apply external power to the alarm input.
Alarm input electrical specification
30VDC @ 1A, 60VDC @ 0.5A
Alarm output electrical specification
To reduce risk of electric shock and fire, the alarm ports must be connected to an IEC 60950/IEC
62368-compliant limited power source (LPS).