75-13
Catalyst 4500 Series Switch, Cisco IOS Software Configuration Guide - Cisco IOS XE 3.9.xE and IOS 15.2(5)Ex
Chapter 75 Configuring Ethernet OAM and CFM
Configuring Ethernet CFM
Configuring Static Remote MEP
To configure Ethernet CFM static remote MEP, perform this task:
Use the
no
form of each command to remove a configuration or to return to the default settings.
The following example illustrates how to configure Ethernet CFM static remote MEP:
Switch(config)#
ethernet cfm domain abc level 3
Switch(config-ecfm)#
service test vlan 5
Switch(config-ecfm-srv)#
continuity-check
Switch(config-ecfm-srv)#
mep mpid 23
Command
Purpose
Step 1
configure terminal
Enter global configuration mode.
Step 2
ethernet cfm domain
domain-name
level
level-id
Define a CFM domain, set the domain level, and enter
ethernet-cfm configuration mode for the domain. The
maintenance level number range is 0 to 7.
Step 3
service
{
ma-name | ma-number | vpn-id vpn
}
{
vlan
vlan-id
[
direction down
] |
port
}
Define a customer service maintenance association name
or number or a VPN ID to be associated with the domain,
and a VLAN ID or peer MEP, and enter
ethernet-cfm-service configuration mode.
•
ma-name
—a string of no more than 100 characters that
identifies the MAID.
•
ma-number
—a value from 0 to 65535.
•
vpn-id
—enter a VPN ID as the
ma-name
.
•
vlan
vlan-id
—VLAN range is from 1 to 4094. You
cannot use the same VLAN ID for more than one
domain at the same level.
•
(Optional)
direction down
—specify the service
direction as down.
•
port
—Configure port MEP, a down MEP that is
untagged and not associated with a VLAN.
Step 4
continuity-check
Enable sending and receiving of continuity check
messages.
Step 5
mep mpid
identifier
Define the static remote maintenance end point identifier.
The range is 1 to 8191.
Step 6
continuity-check static rmep
Enable checking of the incoming continuity check message
from a remote MEP that is configured in the MEP list.
Step 7
end
Return to privileged EXEC mode.
Step 8
show ethernet cfm maintenance-points remote
static
Verify the configuration.
Step 9
show ethernet cfm errors
[
configuration
]
Enter this command after you enable CFM crosscheck to
display the results of the crosscheck operation. Enter the
configuration
keyword to display the configuration error
list.
Step 10
copy running-config startup-config
(Optional) Save your entries in the configuration file.
Содержание Catalyst 4500 Series