69-8
Catalyst 4500 Series Switch, Cisco IOS Software Configuration Guide - Cisco IOS XE 3.9.xE and IOS 15.2(5)Ex
Chapter 69 Configuring Enhanced Object Tracking
Configuring Enhanced Object Tracking Features
Configuring HSRP Object Tracking
To configure a standby HSRP group to track an object and change the HSRP priority based on the object
state, perform this task:
Command
Purpose
Step 1
configure terminal
Enters global configuration mode.
Step 2
track
object-number
{
interface
interface-id
{
line-protocol
| i
p
routing} | ip route
ip-address/prefix-length
{
metric
threshold
| reachability
}
|
list
{
boolean
{
and
|
or
}} |
{
threshold
{
weight
|
percentage
}}}
(Optional) Creates a tracking list to track the configured state and enter
tracking configuration mode.
•
The
object-number
range is from 1 to 500.
•
Enter
interface
interface-id
to select an interface to track.
•
Enter
line-protocol
to track the interface line protocol state or enter
ip
routing to
track the interface IP routing state.
•
Enter
ip route
ip-address/prefix-length
to track the state of an IP route.
•
Enter
metric threshold
to track the threshold metric or enter
reachability
to track if the route is reachable.
The default up threshold is 254 and the default down threshold is 255.
•
Enter
list
to track objects grouped in a list. Configure the list as
described on the previous pages.
–
For
boolean
, see the
“Configuring a Tracked List with a Boolean
Expression” section on page 69-5.
–
For
threshold weight
, see the
“Configuring a Tracked List with a
Weight Threshold” section on page 69-6.
–
For
threshold percentage
, see the
“Configuring a Tracked List with
a Percentage Threshold” section on page 69-7.
Note
Repeat this step for each interface to be tracked.
Step 3
exit
Returns to global configuration mode.
Step 4
interface
interface-id
Enters interface configuration mode.
Step 5
standby
[
group-number
]
ip
[
ip-address
[
secondary
]]
Creates (or enable) the HSRP group by using its number and virtual IP
address.
•
(Optional)
group-number
—Enter a group number on the interface for
which HSRP is being enabled. The range is 0 to 255; the default is 0. If
there is only one HSRP group, you do not need to enter a group number.
•
(Optional on all but one interface)
ip-address
—Specify the virtual IP
address of the hot standby router interface. You must enter the virtual IP
address for at least one of the interfaces; it can be learned on the other
interfaces.
•
(Optional)
secondary
—Specify that the IP address is a secondary hot
standby router interface. If this keyword is omitted, the configured
address is the primary IP address.