55-26
Catalyst 4500 Series Switch, Cisco IOS Software Configuration Guide - Cisco IOS XE 3.9.xE and IOS 15.2(5)Ex
Chapter 55 Configuring Port Security
Configuring Port Security on Voice Ports
Switch#
show port-security address
Secure Mac Address Table
------------------------------------------------------------------------
Vlan Mac Address Type Ports Remaining Age
(mins)
---- ----------- ---- ----- -------------
1 0000.0000.0001 SecureSticky Fa5/1 -
3 0000.0000.0004 SecureSticky Fa5/1 -
------------------------------------------------------------------------
Total Addresses in System (excluding one mac per port) : 1
Max Addresses limit in System (excluding one mac per port) : 3072
Switch#
show running-config interface fastEthernet 5/1
Building configuration...
Current configuration : 344 bytes
!
interface FastEthernet5/1
switchport mode access
switchport voice vlan 3
switchport port-security
switchport port-security maximum 1 vlan voice
switchport port-security maximum 3072
switchport port-security maximum 1 vlan access
switchport port-security mac-address sticky
switchport port-security mac-address sticky 0000.0000.0001
switchport port-security mac-address sticky 0000.0000.0004 vlan voice
end
Switch#
Example 2: Configuring Sticky MAC Addresses for Voice and Data VLANs
This example shows how to configure sticky MAC addresses for voice and data VLANs on Fast Ethernet
interface 5/1 and to verify the configuration:
Switch#
configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#
interface fa5/1
Switch(config-if)#
switchport mode access
Switch(config-if)#
switchport port-security
Switch(config-if)#
switchport port-security maximum 3072
Switch(config-if)#
switchport port-security mac-address sticky 0000.0000.obob vlan voice
Switch(config-if)#
switchport port-security mac-address sticky 0000.0000.0005 vlan access
Switch(config-if)#
end
Note
Sending traffic to the ports causes the system to configure the port with sticky secure addresses.
Switch#
show port-security address
Secure Mac Address Table
------------------------------------------------------------------------
Vlan Mac Address Type Ports Remaining Age
(mins)
---- ----------- ---- ----- -------------
1 0000.0000.0001 SecureSticky Fa5/1 -
1 0000.0000.0002 SecureSticky Fa5/1 -
1 0000.0000.0003 SecureSticky Fa5/1 -
3 0000.0000.0004 SecureSticky Fa5/1 -
1 0000.0000.0005 SecureSticky Fa5/1 -
3 0000.0000.0b0b SecureSticky Fa5/1 -
------------------------------------------------------------------------