12-30
Catalyst 3750-E and 3560-E Switch Software Configuration Guide
OL-9775-08
Chapter 12 Configuring Interface Characteristics
Configuring Ethernet Interfaces
To return to the default setting, use the
no power inline consumption
interface configuration command.
For information about the output of the
show power inline consumption
privileged EXEC command,
see the command reference for this release.
Configuring Power Policing
By default, the switch monitors the real-time power consumption of connected powered devices. You
can configure the switch to police the power usage. By default, policing is disabled.
For more information about the cutoff power value, the power consumption values that the switch uses,
and the actual power consumption value of the connected device, see the “Power Monitoring and Power
Policing” section in the “Configuring Interface Characteristics” chapter of the software configuration
guide for this release.
Beginning in privileged EXEC mode, follow these steps to enable policing of the real-time power
consumption of a powered device connected to a PoE port:
Step 4
power inline consumption
wattage
or
power inline port
maximum_wattage
Configure the power consumption of a powered device connected to a
PoE port on the switch. The range for each device is 4000 to 15400 mW.
The default is 15400 mW.
Configure enhanced PoE to increase the maximum power supplied to a
device (up to 20 W).
Step 5
end
Return to privileged EXEC mode.
Step 6
show power inline consumption
Display the power consumption data.
Step 7
copy running-config startup-config
(Optional) Save your entries in the configuration file.
Command
Purpose
Command
Purpose
Step 1
configure terminal
Enter global configuration mode.
Step 2
interface
interface-id
Specify the physical port to be configured, and enter interface
configuration mode.
Step 3
power inline police
[
action log
]
If the real-time power consumption exceeds the maximum power
allocation on the port, configure the switch to take one of these actions:
•
Shut down the PoE port, turn off power to it, and put it in the
error-dsabled state—Enter the
power inline police
command.
Note
You can enable error detection for the PoE error-disabled cause
by using the
errdisable detect cause inline-power
global
configuration command. You can also enable the timer to recover
from the PoE error-disabled state by using the
errdisable
recovery cause inline-power
interval
interval
global
configuration command.
•
Generate a syslog message while still providing power to the
port—Enter the
power inline police
action log
command.
If you do not enter the
action log
keywords, the default action shuts down
the port and puts the port in the error-disabled state.
Содержание Catalyst 3750-E Series