8-3
Catalyst 3750-E and 3560-E Switch Software Configuration Guide
OL-9775-08
Chapter 8 Configuring SDM Templates
Understanding the SDM Templates
SDM Templates and Switch Stacks
In a Catalyst 3750-E-only or a mixed hardware switch stack, all stack members must use the same SDM
desktop template that is stored on the stack master. When a new switch is added to a stack, the SDM
configuration that is stored on the stack master overrides the template configured on an individual
switch. For more information about stacking, see
Chapter 5, “Managing Switch Stacks.”
You can use the
show switch
privileged EXEC command to see if any stack members are in SDM
mismatch mode. This example shows the output from the
show switch
privileged EXEC command when
an SDM mismatch exists:
Switch#
show switch
Current
Switch# Role Mac Address Priority State
------------------------------------------------------------
*2 Master 000a.fdfd.0100 5 Ready
4 Member 0003.fd63.9c00 5 SDM Mismatch
This is an example of a syslog message notifying the stack master that a stack member is in SDM
mismatch mode:
2d23h:%STACKMGR-6-SWITCH_ADDED_SDM:Switch 2 has been ADDED to the stack (SDM_MISMATCH)
2d23h:%SDM-6-MISMATCH_ADVISE:
2d23h:%SDM-6-MISMATCH_ADVISE:
2d23h:%SDM-6-MISMATCH_ADVISE:System (#2) is incompatible with the SDM
2d23h:%SDM-6-MISMATCH_ADVISE:template currently running on the stack and
2d23h:%SDM-6-MISMATCH_ADVISE:will not function unless the stack is
2d23h:%SDM-6-MISMATCH_ADVISE:downgraded. Issuing the following commands
2d23h:%SDM-6-MISMATCH_ADVISE:will downgrade the stack to use a smaller
2d23h:%SDM-6-MISMATCH_ADVISE:compatible desktop SDM template:
2d23h:%SDM-6-MISMATCH_ADVISE:
2d23h:%SDM-6-MISMATCH_ADVISE: "sdm prefer vlan desktop"
Table 8-2
Approximate Feature Resources Allowed by Dual IPv4-IPv6 Templates
Resource
IPv4-and-IPv6
Default
IPv4-and-IPv6
Routing
IPv4-and-IPv6 VLAN
Unicast MAC addresses
2 K
1.5 K
8 K
IPv4 IGMP groups and multicast routes
1 K
1 K
1 K for IGMP groups
0 for multicast routes
Total IPv4 unicast routes:
3 K
2.75 K
0
•
Directly connected IPv4 hosts
2 K
1.5 K
0
•
Indirect IPv4 routes
1 K
1.25 K
0
IPv6 multicast groups
1 K
1 K
1 K
Directly connected IPv6 addresses
2 K
1.5 K
0
Indirect IPv6 unicast routes
1 K
1.25 K
0
IPv4 policy-based routing ACEs
0
0.25 K
0
IPv4 or MAC QoS ACEs (total)
0.5 K
0.5 K
0.5 K
IPv4 or MAC security ACEs (total)
1 K
0.5 K
1 K
IPv6 security ACEs
0.5 K
0.5 K
0.5 K
Содержание Catalyst 3750-E Series
Страница 48: ...Contents xlviii Catalyst 3750 E and 3560 E Switch Software Configuration Guide OL 9775 08 ...
Страница 52: ...lii Catalyst 3750 E and 3560 E Switch Software Configuration Guide OL 9775 08 Preface ...
Страница 1414: ...Index IN 58 Catalyst 3750 E and 3560 E Switch Software Configuration Guide OL 9775 08 ...