7-28
Cisco Catalyst Blade Switch 3130 and 3032 for Dell Software Configuration Guide
OL-12247-04
Chapter 7 Configuring Switch-Based Authentication
Controlling Switch Access with RADIUS
Beginning in privileged EXEC mode, follow these steps to configure per-server RADIUS server
communication. This procedure is required.
To remove the specified RADIUS server, use the
no radius-server host
hostname
|
ip-address
global
configuration command.
Command
Purpose
Step 1
configure terminal
Enter global configuration mode.
Step 2
radius-server host
{
hostname
|
ip-address
} [
auth-port
port-number
]
[
acct-port
port-number
] [
timeout
seconds
] [
retransmit
retries
] [
key
string
]
Specify the IP address or hostname of the remote RADIUS server host.
•
(Optional) For
auth-port
port-number
, specify the UDP destination
port for authentication requests.
•
(Optional) For
acct-port
port-number
, specify the UDP destination
port for accounting requests.
•
(Optional) For
timeout
seconds
, specify the time interval that the
switch waits for the RADIUS server to reply before resending. The
range is 1 to 1000. This setting overrides the
radius-server timeout
global configuration command setting. If no timeout is set with the
radius-server host
command, the setting of the
radius-server
timeout
command is used.
•
(Optional) For
retransmit
retries
, specify the number of times a
RADIUS request is resent to a server if that server is not responding
or responding slowly. The range is 1 to 1000. If no retransmit value
is set with the
radius-server host
command, the setting of the
radius-server retransmit
global configuration command is used.
•
(Optional) For
key
string
, specify the authentication and encryption
key used between the switch and the RADIUS daemon running on the
RADIUS server.
Note
The key is a text string that must match the encryption key used
on the RADIUS server. Always configure the key as the last item
in the
radius-server host
command. Leading spaces are ignored,
but spaces within and at the end of the key are used. If you use
spaces in your key, do not enclose the key in quotation marks
unless the quotation marks are part of the key.
To configure the switch to recognize more than one host entry associated
with a single IP address, enter this command as many times as necessary,
making sure that each UDP port number is different. The switch software
searches for hosts in the order in which you specify them. Set the timeout,
retransmit, and encryption key values to use with the specific RADIUS
host.
Step 3
end
Return to privileged EXEC mode.
Step 4
show running-config
Verify your entries.
Step 5
copy running-config startup-config
(Optional) Save your entries in the configuration file.