12-24
Catalyst 2928 Switch Software Configuration Guide
OL-23389-01
Chapter 12 Configuring Interface Characteristics
Configuring Ethernet Interfaces
Beginning in privileged EXEC mode, follow these steps to configure amount of power budgeted to a
powered device connected to a specific PoE port:
To return to the default setting, use the
no power inline consumption
interface configuration command.
For information about the output of the
show power inline consumption
privileged EXEC command,
see the command reference for this release.
Configuring Power Policing
By default, the switch monitors the real-time power consumption of connected powered devices. You
can configure the switch to police the power usage. By default, policing is disabled.
For more information about the cutoff power value, the power consumption values that the switch uses,
and the actual power consumption value of the connected device, see the “Power Monitoring and Power
Policing” section.
Beginning in privileged EXEC mode, follow these steps to enable policing of the real-time power
consumption of a powered device connected to a PoE port:
Command
Purpose
Step 1
configure terminal
Enter global configuration mode.
Step 2
no cdp run
(Optional) Disable CDP.
Step 3
interface
interface-id
Specify the physical port to be configured, and enter interface
configuration mode.
Step 4
power inline consumption
wattage
Configure the power consumption of a powered device connected to a
PoE port on the switch.
The range for each de vice is 4000 to 15400 milliwatts. The default is
15400 milliwatts.
Note
When you use this command, we recommend you also enable
power policing.
Step 5
end
Return to privileged EXEC mode.
Step 6
show power inline consumption
Display the power consumption status.
Step 7
copy running-config startup-config
(Optional) Save your entries in the configuration file.
Command
Purpose
Step 1
configure terminal
Enter global configuration mode.
Step 2
interface
interface-id
Specify the physical port to be configured, and enter interface
configuration mode.
Содержание Catalyst 2928
Страница 28: ...Contents xxviii Catalyst 2928 Switch Software Configuration Guide OL 23389 01 ...
Страница 32: ...xxx Catalyst 2928 Switch Software Configuration Guide OL 23389 01 Preface ...
Страница 496: ...26 14 Catalyst 2928 Switch Software Configuration Guide OL 23389 01 Chapter 26 Configuring SPAN Displaying SPAN Status ...
Страница 534: ...29 18 Catalyst 2928 Switch Software Configuration Guide OL 23389 01 Chapter 29 Configuring SNMP Displaying SNMP Status ...
Страница 700: ...Index IN 36 Catalyst 2928 Switch Software Configuration Guide OL 23389 01 ...