This server has the following NIC mode settings that you can choose from:

Shared LOM EXT

(default)—This is the shared LOM extended mode, the factory-default setting. With

this mode, the Shared LOM and Cisco Card interfaces are both enabled. You must select the default

Active-Active

NIC redundancy setting in the following step.

In this NIC mode, DHCP replies are returned to both the shared LOM ports and the Cisco card ports. If
the system determines that the Cisco card connection is not getting its IP address from a Cisco UCS
Manager system because the server is in standalone mode, further DHCP requests from the Cisco card
are disabled. Use the Cisco Card NIC mode if you want to connect to Cisco IMC through a Cisco card
in standalone mode.

Shared LOM

—The 1-Gb/10-Gb Ethernet ports are used to access Cisco IMC. You must select either the

Active-Active

or

Active-standby

NIC redundancy setting in the following step.

Dedicated

—The dedicated management port is used to access Cisco IMC. You must select the

None

NIC redundancy setting in the following step.

Cisco Card

—The ports on an installed Cisco UCS Virtual Interface Card (VIC) are used to access the

Cisco IMC. You must select either the

Active-Active

or

Active-standby

NIC redundancy setting in the

following step.

See also the required VIC Slot setting below.

This server has the following NIC redundancy settings that you can choose from:

None

—The Ethernet ports operate independently and do not fail over if there is a problem. This setting

can be used only with the Dedicated NIC mode.

Active-standby

—If an active Ethernet port fails, traffic fails over to a standby port. Shared LOM and

Cisco Card modes can each use either Active-standby or Active-active settings.

Active-active

(default)—All Ethernet ports are utilized simultaneously. The Shared LOM EXT mode

must use only this NIC redundancy setting. Shared LOM and Cisco Card modes can each use either
Active-standby or Active-active settings.

Accessing the System BIOS

Step 1

Enter the BIOS Setup Utility by pressing the

F2

key when prompted during bootup.

The version and build of the current BIOS are displayed on the Main page of the utility.

Note

Step 2

Use the arrow keys to select the BIOS menu page.

Step 3

Highlight the field to be modified by using the arrow keys.

Step 4

Press

Enter

to select the field that you want to change, and then modify the value in the field.

Step 5

Press the right arrow key until the Exit menu screen is displayed.

Step 6

Follow the instructions on the Exit menu screen to save your changes and exit the setup utility (or press

F10

). You can

exit without saving changes by pressing

Esc

.

Installing the Server

16

Installing the Server

Accessing the System BIOS

Содержание C480M5

Страница 1: ...for important safety information Note IMPORTANT SAFETY INSTRUCTIONS This warning symbol means danger You are in a situation that could cause bodily injury Before you work on any equipment be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents Use the statement number provided at the end of each warning to locate its translation i...

Страница 2: ...Statement 1017 Warning This equipment must be grounded Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available Statement 1024 Warning For Nordic countries Norway Finland Sweden and Denmark this system must be ...

Страница 3: ...following guidelines Plan your site configuration and prepare the site before installing the server See the Cisco UCS Site Preparation Guide for the recommended site planning tasks Ensure that there is adequate space around the server to allow for accessing the server and for adequate airflow The airflow in this server is from front to back Ensure that the air conditioning meets the thermal requir...

Страница 4: ...cautions to ensure that the system remains stable The following guidelines are provided to ensure your safety This unit should be mounted at the bottom of the rack if it is the only unit in the rack When mounting this unit in a partially filled rack load the rack from the bottom to the top with the heaviest component at the bottom of the rack If the rack is provided with stabilizing devices instal...

Страница 5: ... L for left or R for right Note a Align the left inner rail marked L with the left side of the chassis as viewed from the front Align the 10 keyed slots in the rail with the 10 pegs on the side of the chassis b Set the keyed slots over the pegs and then slide the rail toward the front to lock it in place on the pegs c Install the right inner rail marked R to the right side of the chassis as viewed...

Страница 6: ...rack unit b Push the front mounting pegs into the rack post holes until you hear them click and lock c Adjust the slide rail length until it reaches the rear rack post perfectly level Ensure that the rail is perfectly level and that the same height rack post holes are used in the front and rear posts Note d Hold open the rear peg spring latch then push the rear mounting pegs into the rear rack pos...

Страница 7: ...e Caution The rack rail channels are fragile to side loads Install the chassis gently to avoid damaging the rails Note a Align the rear ends of the inner rails that are attached to the server sides with the front ends of the empty intermediate rails on the rack Ensure that the inner rails on the chassis are parallel with the intermediate rails on the rack This could require adjusting the mechanica...

Страница 8: ...the rack with servers installed With the server fully pushed into the slide rails open a hinged slam latch lever on the front of the server and insert a screw through the hole that is under the lever The screw threads into the static part of the rail on the rack post and prevents the server from being pulled out Repeat for the opposite slam latch Depressing the release clips on the inner rails all...

Страница 9: ... tab on arm farthest from server attaches to end of stationary outer slide rail 1 Rear of server 4 CMA tab on arm closest to the server attaches to end of inner slide rail attached to server 2 Step 2 Slide the CMA tab that is closest to the server over the end of the inner rail that is attached to the server Slide the tab over the end of the rail until it clicks and locks Step 3 Pull out the width...

Страница 10: ...der Depress and hold the metal button on the outside of the tab and pivot the tab 180 degrees so that it points toward the rear of the server Figure 6 Reversing the CMA Metal button on outside of tab 2 CMA tab on end of width adjustment slider 1 Initial Server Setup This section describes how to power on the server assign an IP address and connect to server management when using the server in stan...

Страница 11: ...tup through your dedicated management LAN To configure the system remotely you must have a DHCP server on the same network as the system Your DHCP server must be preconfigured with the range of MAC addresses for this server node This server node has a range of six MAC addresses assigned to the Cisco IMC The MAC address printed on the label is the beginning of the range of six contiguous MAC addres...

Страница 12: ... z Base 10 digits 0 through 9 Non alphabetic characters _ Step 4 Continue with Setting Up the System With the Cisco IMC Configuration Utility on page 13 Connecting to the Server Remotely For Setup This procedure requires the following equipment One RJ 45 Ethernet cable that is connected to your management LAN Before you begin To configure the system remotely you must have a DHCP server on the same...

Страница 13: ...r Strong Password The password can have minimum 8 characters maximum 14 characters The password must not contain the user s name The password must contain characters from three of the following four categories English uppercase letters A through Z English lowercase letters a through z Base 10 digits 0 through 9 Non alphabetic characters _ Step 9 Continue with Setting Up the System With the Cisco I...

Страница 14: ...ared LOM EXT mode must use only this NIC redundancy setting Shared LOM and Cisco Card modes can each use either Active standby or Active active settings Step 3 Choose whether to enable DHCP for dynamic network settings or to enter static network settings Before you enable DHCP you must preconfigure your DHCP server with the range of MAC addresses for this server The MAC address is printed on a lab...

Страница 15: ...ly assigned IP and MAC addresses are displayed on the console screen during bootup Note What to do next Use a browser and the IP address of the Cisco IMC to connect to the Cisco IMC management interface The IP address is based upon the settings that you made either a static address or the address assigned by your DHCP server The factory default username for the server is admin The default password...

Страница 16: ...n the following step See also the required VIC Slot setting below This server has the following NIC redundancy settings that you can choose from None The Ethernet ports operate independently and do not fail over if there is a problem This setting can be used only with the Dedicated NIC mode Active standby If an active Ethernet port fails traffic fails over to a standby port Shared LOM and Cisco Ca...

Страница 17: ...pdating the firmware Recommended method for firmware update Use the Cisco Host Upgrade Utility to simultaneously upgrade the Cisco IMC BIOS and component firmware to compatible levels See the Cisco Host Upgrade Utility Quick Reference Guide for your firmware release at the documentation roadmap link below You can upgrade the Cisco IMC and BIOS firmware by using the Cisco IMC GUI interface See the ...

Страница 18: ...Installing the Server 18 Installing the Server Updating the BIOS and Cisco IMC Firmware ...

Отзывы: