14-12
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 14 General Troubleshooting
Command Responses
Trunk Termination Reason Responses, Signaling System 7 Only
The following responses can be returned for the trunk terminations on SS7 trunks. One or more values
can be returned, depending upon the operating conditions of the Call Agent, in addition to the reason
responses listed under
.
•
ACT_LOC_INIT_RESET—Reset circuit at startup as specified by command line argument for SGA
process in the platform.cfg. Remains set until reset circuit (RSC)/group reset (GRS) and release
complete (RLC)/group reset acknowledge (GRA) messages are exchanged with the remote switch.
•
ACT_LOC_MML_RESET—This is set when the
reset
command is issued from the CLI and
remains set until reset is performed. Remains set until RSC/GRS and RLC/GRA messages are
exchanged with the remote switch.
•
ACT_LOC_QUERY—This is set when the a
diagnostic
command is issued from the CLI to perform
a circuit query and remains set until circuit query message (CQM) and circuit query response (CQR)
messages are exchanged with a remote switch.
•
ACT_LOC_UPU—This is set when ITP informs that the user part is unavailable and remains set
until a circuit verification response (CVR) is received or the ITP informs that the user part is
available. The first incoming message will also clear this response.
•
ACT_LOC_VALIDATE—This is set when the a
diagnostic
command is issued from the CLI to
perform a circuit validation and remains set until circuit validation test (CVT) and CVR messages
are exchanged with the remote switch.
•
ACT_LOC_COTTEST—This is set when the a
diagnostic
command is issued from the CLI to
perform a customer-originated trace (COT) test and remains set until SRINI TO CHECK messages
are exchanged with the remote switch.
•
ACT_LOC_STOP—This is set to clear a call when a term-fault is received.
•
BLK_LOC_UPU—This is set when a trunk is blocked because user part is unavailable.
•
DES_LOC_GRACE—Local hardware restart in progress (RSIP) graceful.
•
DES_LOC_SIG—SS7—This is set when cannot exchange messages with PSTN network (a
signaling fault):
–
dpc unavailable
–
user part unavailable
–
stcp association unavailable
–
Signaling link is faulty.
–
dpc congestion
•
SIGNALLING-FAULT-This is set to indicate that the BTS 10200 processed a
DES_LOC_SIG—SS7 signaling fault.
•
DES_LOC_FORCE—Local hardware failure.
•
DES_LOC_MML—MMLQ—This is set when a
control
command is issued with mode=graceful
and target-state=OOS. Also set during CQR processing.
•
DES_LOC_UPU—This is set when user part is unavailable.
•
JOB_PENDING—Ongoing job in progress. There is an ongoing action of message exchange with
the remote switch.
•
JOB_REC—Job was received by the message definition language (MDL) component and is being
processed.