![Cisco BTS 10200 Softswitch Скачать руководство пользователя страница 490](http://html.mh-extra.com/html/cisco/bts-10200-softswitch/bts-10200-softswitch_troubleshooting-manual_67550490.webp)
10-122
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 10 Signaling Troubleshooting
Monitoring Signaling Events
Emergency Trunks Become Locally Blocked—Signaling (153)
The Emergency Trunks Become Locally Blocked alarm (critical) indicates that an emergency trunk
(CAS, SS7, or ISDN) is locally blocked. To troubleshoot and correct the cause of the Emergency Trunks
Become Locally Blocked alarm, refer to
“Emergency Trunks Become Locally Blocked—Signaling
.
Emergency Trunks Become Remotely Blocked—Signaling (154)
The Emergency Trunks Become Remotely Blocked alarm (critical) indicates that an emergency trunk
(CAS, SS7, or ISDN) is remotely blocked. To troubleshoot and correct the cause of the Emergency
Trunks Become Remotely Blocked alarm, refer to
“Emergency Trunks Become Remotely
Blocked—Signaling (154)” section on page 10-157
Packet Cable Multi-Media Unsolicited Gate Delete—Signaling (155)
The Packet Cable Multi-Media Unsolicited Gate Delete event serves as an informational alert that an
error condition was encountered by the CMTS. To correct the cause of the event, check the alarms and
warnings from the CMTS.
Integrated Services Digital Network Signaling Gateway Down—Signaling
(156)
The Integrated Services Digital Network Signaling Gateway Down alarm (major) indicates that the BTS
10200 system cannot communicate with the ISDN gateway. To troubleshoot and correct the cause of the
Integrated Services Digital Network Signaling Gateway Down alarm, refer to
Digital Network Signaling Gateway Down—Signaling (156)” section on page 10-157
Integrated Services Digital Network Signaling Gateway Inactive—Signaling
(157)
The Integrated Services Digital Network Signaling Gateway Inactive alarm (major) indicates that a
shutdown
command has been executed in the application server on the ISDN gateway side. To
troubleshoot and correct the cause of the Integrated Services Digital Network Signaling Gateway
Inactive alarm, refer to
“Integrated Services Digital Network Signaling Gateway Inactive—Signaling
.
Invalid Integrated Services Digital Network Interface
Identification—Signaling (158)
The Invalid Integrated Services Digital Network Interface Identification event serves as a warning that
an interface ID is not configured correctly on the ISDN gateway side. To correct the cause of the event,
configure the D-channel correctly on the gateway side. The D-channel configuration on the call-agent
side should match with that on the gateway side.