Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 10 Signaling Troubleshooting
Signaling Events and Alarms
SIGNALING (151)
To troubleshoot and correct the cause of the alarm, refer to the
“Subscriber Line Faulty—Signaling
.
SIGNALING (152)
For additional information, refer to the
“Termination Transient Error Received—Signaling (152)”
.
Note
Refer to the
“Obtaining Documentation and Submitting a Service Request” section on page lvi
detailed instructions on contacting Cisco TAC and opening a service request.
DESCRIPTION
Subscriber Line Faulty
SEVERITY
MINOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
End Point /Termination - STRING [54]
Media Gateway Type - STRING [54]
Error Details - STRING [54]
PRIMARY
CAUSE
The residential gateway returned an error code in response to a command from the MGW.
PRIMARY
ACTION
Try controlling subscriber termination to OOS and back to INS using the BTS 10200 CLI command.
If the problem persist after more calls, check the configuration in the BTS 10200 and the RGW. If the
error codes returned by the MGW are harmless, it can be suppressed by adding a new entry in
MGCP-RETCODE-ACTION table and by changing the EP-ACTION to RESET/NONE.
DESCRIPTION
Termination Transient Error Received
SEVERITY
INFO
THRESHOLD
100
THROTTLE
0
DATAWORDS
Entity Name–STRING [40]
General Context–STRING [40]
Specific Context–STRING [40]
Failure Context–STRING [40]
PRIMARY
CAUSE
MGCP signaling interop errors have occurred.
PRIMARY
ACTION
Notify customer support. (Contact Cisco TAC.)