![Cisco BTS 10200 Softswitch Скачать руководство пользователя страница 430](http://html.mh-extra.com/html/cisco/bts-10200-softswitch/bts-10200-softswitch_troubleshooting-manual_67550430.webp)
10-62
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 10 Signaling Troubleshooting
Signaling Events and Alarms
SIGNALING (113)
To troubleshoot and correct the cause of the alarm, refer to the
“Signaling Gateway Failure—Signaling
.
Note
When a port on a ITP is removed from service using the
shut
command, multiple Signaling 113 and 114
alarms are raised (ON status). When the port is recovered by cycling the ITP power, all alarms raised
are cleared (OFF status) and are removed from CURRENT_ALARM table. However, not all cleared
alarms (OFF status) are displayed on the subscriber terminal. Only the first instance of the cleared alarms
(OFF status) with a variation in TYPE, NUMBER, and COMPONENT-ID
are
displayed. Multiple
instances of the cleared alarms (OFF status) where the TYPE, NUMBER, and COMPONENT-ID are
identical
are not
displayed.
DESCRIPTION
Signaling Gateway Failure
SEVERITY
MAJOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
Signaling Gateway ID–STRING [17]
PRIMARY
CAUSE
All of the associated signaling gateway processes are out-of-service.
PRIMARY
ACTION
Determine why each of the associated SGP processes is out-of-service (see the SGP alarm definition).