10-60
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 10 Signaling Troubleshooting
Signaling Events and Alarms
SIGNALING (110)
To troubleshoot and correct the cause of the alarm, refer to the
Out-of-Service—Signaling (110)” section on page 10-150
.
SIGNALING (111)
To troubleshoot and correct the cause of the alarm, refer to the
“Stream Control Transmission Protocol
.
DESCRIPTION
Signaling Gateway Group is Out-of-Service
SEVERITY
CRITICAL
THRESHOLD
100
THROTTLE
0
DATAWORDS
SG Group ID–STRING [17]
PRIMARY
CAUSE
All Stream Control Transmission Protocol (SCTP) associations between the CA and the SGs are
out-of-service.
PRIMARY
ACTION
Make sure all Ethernet connections on the CA and the SGs are plugged in. Also make sure all of the
associated IP routers are operational.
SECONDARY
CAUSE
The MTP3 user adapter (M3UA) layer is down between the CA and the SGs.
SECONDARY
ACTION
Use the Cisco snooper application to determine why the M3UA layer is down.
DESCRIPTION
Stream Control Transmission Protocol Association Degraded (One of Two Internet Protocol
Connections Down) (SCTP Association Degraded (One of Two IP connections Down))
SEVERITY
MAJOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
SCTP Association ID–STRING [17]
Destination IP Address–STRING [11]
PRIMARY
CAUSE
A single Ethernet connection on the CA or the SGP is unplugged or severed.
PRIMARY
ACTION
Plug in all of the Ethernet connections or repair if severed.
SECONDARY
CAUSE
A SCTP communication problem–protocol timeout.
SECONDARY
ACTION
Use the Cisco snooper application to determine why the SCTP association is degraded.