10-12
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 10 Signaling Troubleshooting
Signaling Events and Alarms
SIGNALING (20)
To troubleshoot and correct the cause of the alarm, refer to the
“Link Set Congestion—Signaling (20)”
.
SIGNALING (21)
To troubleshoot and correct the cause of the alarm, refer to the
“Route Set Failure—Signaling (21)”
.
DESCRIPTION
Link Set Congestion
SEVERITY
MAJOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
Link Set No–ONE_BYTE
Link Set Name–STRING [8]
Congestion Level–ONE_BYTE
PRIMARY
CAUSE
Issued when the specified SS7 link set is experiencing congestion.
PRIMARY
ACTION
Monitor event reports at the network level to determine if the traffic load on the specified SS7 link set
is too high on the local end, or if the remote end is lagging in processing the traffic.
SECONDARY
ACTION
Verify that the SS7 link set has not degraded in quality.
TERNARY
ACTION
Verify that the traffic load has not become unbalanced if multiple SS7 link sets are used.
SUBSEQUENT
ACTION
Verify that local SS7 signaling adapter process is running normally.
DESCRIPTION
Route Set Failure
SEVERITY
MAJOR
THRESHOLD
200
THROTTLE
0
DATAWORDS
Route Set No–TWO_BYTES
Route Set Name–STRING [8]
PRIMARY
CAUSE
Issued when the specified route set has experienced a failure.
PRIMARY
ACTION
Verify that the processing complex supporting the route set is functional.
SECONDARY
ACTION
Monitor event reports at the network level to determine the failing component and to verify its restoral
to service.