
6-14
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 6 Database Troubleshooting
Database Events and Alarms
DATABASE (16)
To troubleshoot and correct the cause of the alarm, refer to the
“Table Size Exceeds Critical Threshold
Limit—Database (16)” section on page 6-33
DATABASE (17)
To troubleshoot and correct the cause of the alarm, refer to the
“Data Replication Failed—Database (17)”
DESCRIPTION
Table Size Exceeds Critical Threshold Limit
SEVERITY
CRITICAL
THRESHOLD
100
THROTTLE
0
DATAWORDS
Table Name–STRING [32]
PRIMARY
CAUSE
The critical threshold limit has been exceeded.
PRIMARY
ACTION
N/A
DESCRIPTION
Data Replication Failed
SEVERITY
MAJOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
Replication-Stage–STRING [40]
Table Name–STRING [40]
Index–FOUR_BYTES
Table ID–TWO_BYTES
PRIMARY
CAUSE
The index size is out of range.
SECONDARY
CAUSE
Record the index size mismatch.