The following image shows the
–
48 VDC power supplies for the Cisco ASR 1001 Router.
Figure 206:
–
48 VDC Power Supply for the Cisco ASR 1001 Router
The output voltage alarm is declared when the output voltage is below the low end of the minimum or above
the high end of the maximum limits. When the output voltage is above the high end of the minimum or below
the low end of the maximum limits, the red state will not be activated.
The following table shows the
–
48 VDC power supply output voltage alarm ranges.
Table 85:
–
48 VDC Power Supply Output Voltage Alarm Threshold Ranges
Maximum
Minimum
Output
12.8-13.8V
10.0-11.2V
12V
None
2.6 - 3.0 V
3.3V
Power Cords Supported by the Cisco ASR 1001 Router
The following table lists the power cords that are supported by the Cisco ASR 1001 Router.
Table 86: Power Cords Supported by the Cisco ASR 1001 Router
Description
Power Cord Item Number
AC Power Cable ANSI 220VAC Right Exit
15454-M-ACCBL-R2
Power Cord, 110 V, Right Angle
CAB-AC-RA
Plug, Power Cord, Australian, 10 A, Right Angle
CAB-ACA-RA
Power Cord China, Right Angle
CAB-ACC-RA
Power Cord Europe, Right Angle
CAB-ACE-RA
Power Cord, Italian, Right Angle
CAB-ACI-RA
Cisco ASR 1000 Series Router Hardware Installation Guide
424
Cisco ASR 1001 Router Overview and Installation
Power Supplies in the Cisco ASR 1001 Router
Содержание ASR 1001
Страница 2: ... 2013 2017 Cisco Systems Inc All rights reserved ...
Страница 20: ...Cisco ASR 1000 Series Router Hardware Installation Guide xx Contents ...
Страница 30: ...Cisco ASR 1000 Series Router Hardware Installation Guide xxx Preface Warning Definition ...
Страница 32: ...Cisco ASR 1000 Series Router Hardware Installation Guide xxxii Preface Warning Definition ...
Страница 698: ...Cisco ASR 1000 Series Router Hardware Installation Guide 664 MIBs Overview MIBs for the Cisco ASR 1001 Router ...