Cisco ASR-1000-SIP10 Скачать руководство пользователя страница 66

   

4-2

Cisco ASR 1000 Series Aggregation Services Routers SIP and SPA Hardware Installation Guide

OL-14126-03

Chapter 4      Preparing to Install a SIP or a Shared Port Adapter

  Safety Guidelines

Safety Warnings

Safety warnings appear throughout this publication in procedures that, if performed incorrectly, might 
harm you. A warning symbol precedes each warning statement.

Warning Definition

Warning

IMPORTANT SAFETY INSTRUCTIONS

This warning symbol means danger. You are in a situation that could cause bodily injury. Before you 
work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar 
with standard practices for preventing accidents. Use the statement number provided at the end of 
each warning to locate its translation in the translated safety warnings that accompanied this 
device. 

Statement 1071

SAVE THESE INSTRUCTIONS

Waarschuwing

BELANGRIJKE VEILIGHEIDSINSTRUCTIES

Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die lichamelijk letsel kan 
veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij 
elektrische schakelingen betrokken risico's en dient u op de hoogte te zijn van de standaard 
praktijken om ongelukken te voorkomen. Gebruik het nummer van de verklaring onderaan de 
waarschuwing als u een vertaling van de waarschuwing die bij het apparaat wordt geleverd, wilt 
raadplegen.

BEWAAR DEZE INSTRUCTIES

Varoitus

TÄRKEITÄ TURVALLISUUSOHJEITA

Tämä varoitusmerkki merkitsee vaaraa. Tilanne voi aiheuttaa ruumiillisia vammoja. Ennen kuin 
käsittelet laitteistoa, huomioi sähköpiirien käsittelemiseen liittyvät riskit ja tutustu 
onnettomuuksien yleisiin ehkäisytapoihin. Turvallisuusvaroitusten käännökset löytyvät laitteen 
mukana toimitettujen käännettyjen turvallisuusvaroitusten joukosta varoitusten lopussa näkyvien 
lausuntonumeroiden avulla.

SÄILYTÄ NÄMÄ OHJEET

Attention

IMPORTANTES INFORMATIONS DE SÉCURITÉ 

Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation pouvant 
entraîner des blessures ou des dommages corporels. Avant de travailler sur un équipement, soyez 
conscient des dangers liés aux circuits électriques et familiarisez-vous avec les procédures 
couramment utilisées pour éviter les accidents. Pour prendre connaissance des traductions des 
avertissements figurant dans les consignes de sécurité traduites qui accompagnent cet appareil, 
référez-vous au numéro de l'instruction situé à la fin de chaque avertissement.

CONSERVEZ CES INFORMATIONS

Содержание ASR-1000-SIP10

Страница 1: ... Tasman Drive San Jose CA 95134 1706 USA http www cisco com Tel 408 526 4000 800 553 NETS 6387 Fax 408 527 0883 Cisco ASR 1000 Series Aggregation Services Routers SIP and SPA Hardware Installation Guide November 24 2008 Text Part Number 3OL 14126 02 ...

Страница 2: ...the equipment into an outlet that is on a different circuit from the television or radio That is make certain the equipment and the television or radio are on circuits controlled by different circuit breakers or fuses Modifications to this product not authorized by Cisco Systems Inc could void the FCC approval and negate your authority to operate the product The Cisco implementation of TCP header ...

Страница 3: ...ibility 2 1 SPA Interface Addresses on SIPs 2 2 Identifying Slots and Subslots for SIPs and SPAs 2 2 Specifying the Slot Location for a SIP 2 2 Specifying the SIP Subslot Location for a SPA 2 4 Cisco ASR 1000 Series SPA Interface Processor Overview 2 5 Cisco ASR1000 SIP10 LEDs 2 5 Cisco ASR1000 SIP10 Physical Specifications 2 6 C H A P T E R 3 Overview Cisco ASR 1000 Series Aggregation Services Ro...

Страница 4: ...1 Port Channelized STM 1 OC 3 SPA Cables and Connectors 3 13 4 Port and 8 Port Fast Ethernet SPA Overview 3 14 4 Port and 8 Port Fast Ethernet SPA LEDs 3 14 4 Port and 8 Port Fast Ethernet SPA Cables Connectors and Pinouts 3 15 1 Port 10 Gigabit Ethernet SPA Overview 3 16 1 Port 10 Gigabit Ethernet SPA LEDs 3 16 1 Port 10 Gigabit Ethernet SPA XFP Optical Transceiver Modules Connectors and Cables 3...

Страница 5: ...R SPA Overview 3 35 2 Port and 4 Port OC 48c STM 16 POS RPR SPA LEDs 3 35 2 Port and 4 Port OC 48c STM 16 POS RPR SPA Interface Specifications 3 36 2 Port and 4 Port OC 48c STM 16 POS RPR SPA Cables Optical Transceiver Modules and Connectors 3 36 OC 48 Module Connections 3 37 1 Port OC 12c STM 4 POS SPA Overview 3 38 1 Port OC 12c STM 4 POS SPA LEDs 3 38 1 Port OC 12c STM 4 POS SPA Interface Speci...

Страница 6: ...n of a SPA Configuration Example 5 8 SIP Installation and Removal 5 8 C H A P T E R 6 Installing and Removing a Shared Port Adapter 6 1 Handling SPAs 6 1 SPA Installation and Removal 6 2 Installing a SPA in a SIP 6 3 Removing a SPA from a SIP 6 3 Online Insertion and Removal 6 4 Optical Device Maintenance 6 4 Cleaning Optical Devices 6 4 Checking the Installation 6 4 Verifying the Installation 6 4...

Страница 7: ... processors SIPs and shared port adapters SPAs that are supported on the Cisco ASR 1000 Series Aggregation Services Routers This document also describes how to install the supported SIPs and SPAs and how to troubleshoot the installation Document Revision History The Document Revision History records technical changes to this document The table shows the Cisco IOS software release number and docume...

Страница 8: ...com type Software Advisor in the SEARCH box and click GO Click the link for the Software Advisor tool Section Title Description Chapter 1 SIP and SPA Product Overview Provides an introduction to SPA interface processors SIPs and shared port adapters SPAs Chapter 2 Overview Cisco ASR 1000 Series Aggregation Services Routers SIPs Provides a SIP and SPA compatibility summary For each supported SIP pr...

Страница 9: ...and Safety Information for the Cisco ASR 1000 Series Aggregation Services Routers Obtaining Documentation and Submitting a Service Request For information on obtaining documentation submitting a service request and gathering additional information see the monthly What s New in Cisco Product Documentation which also lists all new and revised Cisco technical documentation at http www cisco com en US...

Страница 10: ...x Cisco ASR 1000 Series Aggregation Services Routers SIP and SPA Hardware Installation Guide OL 14126 03 Preface ...

Страница 11: ...reases modularity flexibility and density across Cisco routers for network connectivity This section describes the SIPs and SPAs and provides some guidelines for their use SPA Interface Processors The following list describes some of the general characteristics of a SIP A SIP is a carrier card that inserts into a router slot like a line card It provides no network connectivity on its own A SIP con...

Страница 12: ...co IOS command line interface CLI Either a blank filler plate or a functional SPA should reside in every subslot of a SIP during normal operation to maintain cooling integrity Blank filler plates are available in single height form only SPAs support online insertion and removal OIR They can be inserted or removed independently from the SIP SIPs also support OIR with SPAs inserted in their subslots...

Страница 13: ... 4 Port Serial Interface SPA SPA 4XT Serial Yes 8 Port Channelized T1 E1 Serial SPA SPA 8XCHT1 E1 Yes 1 Port Channelized STM 1 OC 3 SPA SPA 1XCHSTM1 OC3 Yes Table 1 2 SIP and SPA Compatibility Table for Ethernet SPAs SPA Product ID SIP Supported Cisco ASR1000 SIP10 4 Port and 8 Port Fast Ethernet SPA SPA 4X1FE TX V2 SPA 8X1FE TX V2 Yes 1 Port 10 Gigabit Ethernet SPA SPA 1X10GE L V2 Yes 2 Port Giga...

Страница 14: ...FP 10GZR OC192LR 5 Port Gigabit Ethernet SPA SFP GE S SFP GE L SFP GE Z SFP GE T GLC FE 100FX 2 Port Gigabit Ethernet SPA 8 Port Gigabit Ethernet SPA SFP GE S SFP GE L SFP GE Z SFP GE T 10 Port Gigabit Ethernet SPA SFP GE S SFP GE L SFP GE Z GLC FE 100FX Table 1 5 Gigabit Ethernet SPA CWDM Optics Compatibility for All Gigabit Ethernet SPAs Supported on the Cisco ASR 1000 Series Routers Qualified O...

Страница 15: ...bit Ethernet SPA 8 Port Gigabit Ethernet SPA 10 Port Gigabit Ethernet Spa DWDM SFP 3033 DWDM SFP 3112 DWDM SFP 3190 DWDM SFP 3268 DWDM SFP 3425 DWDM SFP 3504 DWDM SFP 3582 DWDM SFP 3661 DWDM SFP 3819 DWDM SFP 3898 DWDM SFP 3977 DWDM SFP 4056 DWDM SFP 4214 DWDM SFP 4294 DWDM SFP 4373 DWDM SFP 4453 DWDM SFP 4612 DWDM SFP 4692 DWDM SFP 4772 DWDM SFP 4851 DWDM SFP 5012 DWDM SFP 5092 DWDM SFP 5172 DWDM...

Страница 16: ...ity Table 1 7 POS SPA SFP and CWDM Optics Compatibility SPA Qualified Optics Modules Cisco Part Numbers 2 Port and 4 Port OC 3c STM 1 POS SPA SFP OC3 MM SFP OC3 SR SFP OC3 IR1 SFP OC3 LR1 SFP OC3 LR2 2 Port and 4 Port OC 48c STM 16 POS RPR SPA SFP OC48 SR SFP OC48 IR1 SFP OC48 LR2 1 Port OC 12c STM 4 POS SPA SFP OC12 MM SFP OC12 SR SFP OC12 IR1 SFP OC12 LR1 SFP OC12 LR2 ...

Страница 17: ...e SIPs that are supported on the Cisco ASR 1000 Series Routers are shown in Table 2 1 Note The Description column indicates the aggregate bandwidth supported by the SIP across all subslots not per SPA subslot Checking Hardware and Software Compatibility To check the minimum software requirements of Cisco IOS software with the hardware installed on your router Cisco maintains the Software Advisor t...

Страница 18: ...pecify the physical locations of a SIP and SPA on the Cisco ASR 1000 Series Routers within the command line interface CLI to configure or monitor the devices Specifying the Slot Location for a SIP The Cisco ASR 1000 Series Routers support different chassis models each of which supports a certain number of chassis slots The Cisco ASR 1006 Router supports three chassis slots for SIPs The Cisco ASR 1...

Страница 19: ...or example to display status and slot related information about the SIP installed in any of the chassis slots enter the following command Router show platform Chassis type ASR1006 Slot Type State Insert time ago 0 ASR1000 SIP10 ok 2d21h 0 0 SPA 2X1GE V2 ok 2d21h 0 1 SPA 2X1GE V2 ok 2d21h 0 2 SPA 2X1GE V2 ok 2d21h 0 3 SPA 1XOC12 POS ok 2d21h 1 ASR1000 SIP10 ok 22 46 22 1 0 SPA 1X10GE L V2 ok 22 45 ...

Страница 20: ...ote In the Cisco ASR 1002 Router SIP subslot 0 is not available for SPA insertion It is the slot that is used for the integrated Route Processor and Gigabit Ethernet ports Figure 2 2 shows the SPA numbering sequence on a Cisco ASR 1000 Series Routers SIP Figure 2 2 Cisco ASR 1000 Series SIP SPA Numbering The SIP subslot numbering is indicated by a small numeric label beside the subslot on the face...

Страница 21: ... ASR1000 RP1 ok active 3d20h F0 ASR1000 ESP10 ok active 3d20h P0 ASR1006 PWR AC ok 3d20h P1 ASR1006 FAN ok 3d20h Slot CPLD Version Firmware Version 0 07091401 12 2 33r XN2 1 07091401 12 2 33r XN2 2 07091401 12 2 33r XN2 R0 07082312 12 2 33r XN2 Cisco ASR 1000 Series SPA Interface Processor Overview The following sections describe the Cisco ASR1000 SIP10 Cisco ASR1000 SIP10 LEDs page 2 5 Cisco ASR1...

Страница 22: ...ow On The Cisco ASR1000 SIP10 is loading Green On The Cisco ASR1000 SIP10 is online Off Off The Cisco ASR1000 SIP10 is powered off PWR Green On The Cisco ASR1000 SIP10 is powered on Off Off The Cisco ASR1000 SIP10 is powered off Table 2 4 Cisco ASR1000 SIP10 Physical Specifications Description Specifications Physical dimension HxWxD 1 630 inches 41 4 mm x 16 725 inches 424 8 mm x 14 187 inches 360...

Страница 23: ...erface SPA Overview page 3 6 8 Port Channelized T1 E1 Serial SPA Overview page 3 10 1 Port Channelized STM 1 OC 3 SPA Overview page 3 12 Ethernet SPAs 4 Port and 8 Port Fast Ethernet SPA Overview page 3 14 1 Port 10 Gigabit Ethernet SPA Overview page 3 16 2 Port Gigabit Ethernet SPA Overview page 3 19 5 Port Gigabit Ethernet SPA Overview page 3 21 8 Port Gigabit Ethernet SPA Overview page 3 23 10 ...

Страница 24: ...hoose a product family or enter a specific product number to search for the minimum supported software release needed for your hardware 2 Port and 4 Port Clear Channel T3 E3 Serial SPA Overview The following sections describe the 2 Port and 4 Port T3 E3 Clear Channel Serial SPA 2 Port and 4 Port T3 E3 Clear Channel Serial SPA LEDs page 3 2 2 Port and 4 Port T3 E3 Clear Channel Serial SPA Interface...

Страница 25: ...4 Port T3 E3 Clear Channel Serial SPA are 75 ohm coaxial Siemax types with one connector and cable for transmit TX and one for receive RX The following cables can be used with the 2 Port and 4 Port T3 E3 Clear Channel Serial SPA The cables have BNC connectors on one end and the Siemax connectors on the other CAB T3E3 RF BNC M T3 or E3 Cable 1 0 2 3 RF to BNC Male 10 feet CAB T3E3 RF BNC F T3 or E3...

Страница 26: ...PA LEDs The 2 Port and 4 Port Channelized T3 Serial SPA has three types of LEDs two LEDs for each port on the SPA and one STATUS LED as shown in Figure 3 2 Figure 3 2 4 Port Channelized T3 Serial SPA Faceplate Table 3 2 2 Port and 4 Port T3 E3 Clear Channel Serial SPA Connectors Connector Label Meaning TX Transmitted signals appear on the center contact and the outer shield is ground for the 75 oh...

Страница 27: ...d 4 Port Channelized T3 Serial SPA are 75 ohm coaxial Siemax types with one connector and cable for transmit TX and one for receive RX The following cables can be used with the 2 Port and 4 Port Channelized T3 Serial SPA The cables have BNC connectors on one end and the Siemax connectors on the other CAB T3E3 RF BNC M T3 or E3 Cable 1 0 2 3 RF to BNC Male 10 feet CAB T3E3 RF BNC F T3 or E3 Cable 1...

Страница 28: ...gure 3 3 4 Port Serial Interface SPA Faceplate Table 3 5 describes the 4 Port Serial Interface SPA LEDs Table 3 4 2 Port and 4 Port Channelized T3 Serial SPA Connectors Connector Label Meaning TX Transmitted signals appear on the center contact and the outer shield is ground for the 75 ohm RG 59 coaxial cable you attach to the TX Siemax connector RX Received signals appear on the center contact an...

Страница 29: ...he SPA port is not enabled Green On The SPA port is enabled and DTR DSR RTS CTS or DCD is active Amber On The SPA port is enabled and local loopback or internal loopback is active STATUS Off Off The SPA is powered off power is not within required specification or Status On conditions not met Green On The SPA is powered on and operational power is within required specification and initialization is...

Страница 30: ...rface ports The serial end of the Smart Serial cable is a 26 pin connector Table 3 6 lists the 4 Port Serial Interface SPA cable interfaces Figure 3 4 shows the Smart Serial cable connectors Table 3 6 4 Port Serial Interface SPA Cables Product Number Cable Type Length Connector Type CAB SS V35MT V 35 DTE 10 feet 3 meters Male CAB SS V35FC V 35 DCE 10 feet 3 meters Female CAB SS 232MT EIA TIA 232 D...

Страница 31: ... Smart Serial connectors that interface at the 4 Port Serial Interface SPA ports Router connections EIA TIA 449 V 35 X 21 Network connections at the modem or CSU DSU 205059 EIA TIA 232 EIA 530 Table 3 7 Smart Serial Connector Pinouts Pin Signal Pin Signal 1 O_TXD RXD 14 O_TXD RXD 2 O_TXCE RXC 15 O_TXCE RXC 3 B_TXC TXC 16 B_TXC TXC 4 I_RXC TXCE 17 I_RXC TXCE 5 I_RXD TXD 18 I_RXD TXD 6 B_DCD DCD 19 ...

Страница 32: ...ized T1 E1 Serial SPA has three types of LEDs two LEDs for each port on the SPA and one STATUS LED as shown in Figure 3 5 Figure 3 5 8 Port Channelized T1 E1 Serial SPA Faceplate Table 3 8 describes the 8 Port Channelized T1 E1 Serial SPA LEDs 12 I_DSR DTR 25 I_DSR DTR 13 B_LL LL 26 GND Table 3 7 Smart Serial Connector Pinouts Pin Signal Pin Signal 1 C A Carrier Alarm LED 3 STATUS LED 2 A L Active...

Страница 33: ... Caution Shielded T1 E1 cables must be used to comply with FCC EN55022 CISPR22 Class A emissions requirements 8 Port Channelized T1 E1 Serial SPA Cables Connectors and Pinouts Figure 3 6 shows an RJ 45 connector Figure 3 6 RJ 45 Connector Table 3 9 describes the signals and connector pinouts for RJ 45 cable connectors A L Off Off Port is not enabled by software Green On Port is enabled by software...

Страница 34: ...C 3 SPAhas three types of LEDs a C A LED an A L LED and a STATUS LED as shown in Figure 3 7 Figure 3 7 1 Port Channelized STM 1 OC 3 SPA Faceplate Table 3 10 describes the 1 Port Channelized STM 1 OC 3 SPALEDs 7 NC No connection 8 NC No connection Table 3 9 RJ 45 Connector Pinouts continued Pin Signal Description 1 C A Carrier Alarm LED 3 STATUS LED 2 A L Active Loopback LED SPA 1XCHSTM1 OC3 S T A...

Страница 35: ...7 and Management Information Base MIB II RFC 1213 1 Port Channelized STM 1 OC 3 SPA Cables and Connectors The 1 Port Channelized STM 1 OC 3 SPAuses a small form factor pluggable SFP optical transceiver module installed in the port for SONET and SDH single mode and multimode optical fiber connection See Figure 3 8 Figure 3 8 SFP Optics Module The SFP optical transceiver modules used with the 1 Port...

Страница 36: ...rt Channelized STM 1 OC 3 SPA equipped routers back to back Long range SFP optical transceiver modules for long reach configurations cannot be connected back to back without using an attenuator between the two of them Figure 3 9 LC Type Cables 4 Port and 8 Port Fast Ethernet SPA Overview The following sections describe the 4 Port and 8 Port Fast Ethernet SPA 4 Port and 8 Port Fast Ethernet SPA LED...

Страница 37: ... the RJ 45 pinout in Table 3 12 proper common mode line terminations should be used for the unused Category 5 UTP cable pairs 4 5 and 7 8 Common mode termination reduces the contributions to electromagnetic interference EMI and susceptibility to common mode sources Wire pairs 4 5 and 7 8 are actively terminated in the RJ 45 port circuitry in the 4 Port and 8 Port Fast Ethernet SPA Table 3 11 4 Por...

Страница 38: ...to a Hub or Repeater Figure 3 13 Crossover Cable Pinout RJ 45 Connections Between Routers 1 Port 10 Gigabit Ethernet SPA Overview The following sections describe the 1 Port 10 Gigabit Ethernet SPA 1 Port 10 Gigabit Ethernet SPA LEDs page 3 16 1 Port 10 Gigabit Ethernet SPA XFP Optical Transceiver Modules Connectors and Cables page 3 17 1 Port 10 Gigabit Ethernet SPA LEDs The 1 Port 10 Gigabit Ethe...

Страница 39: ...above listed small form factor pluggable modules XFPs are the only optical transceiver modules qualified for use Use a single mode optical fiber that has a modal field diameter of 8 7 0 5 microns nominal diameter is approximately 10 125 microns to connect your router to a network Figure 3 15 shows the cable type for use with the XFP optical transceiver module on the 1 Port 10 Gigabit Ethernet SPA ...

Страница 40: ...to detector transimpedance amplifier and passes it to an output driver See the label on the XFP module for technology type and model Figure 3 16 shows an XFP module and Table 3 14 shows the XFP module specifications Figure 3 16 XFP Module Table 3 14 XFP Module Specifications for the 1 Port 10 Gigabit Ethernet SPA Specification Description Dimensions height x width x length 12 5 mm x 18 35 mm x 71 ...

Страница 41: ...SPA LEDs The 2 Port Gigabit Ethernet SPA has two types of LEDs an A L LED for each port on the SPA and one STATUS LED as shown in Figure 3 17 Figure 3 17 2 Port Gigabit Ethernet SPA Faceplate Table 3 16 describes the 2 Port Gigabit Ethernet SPA LEDs RX overload 10GLR SR 1 0 5 dBm 10GER IR 2 1 0 dBm 10GZR LR 2 7 0 dBm Maximum receiver power damage 10GLR SR 1 5 dBm 10GER IR 2 5 dBm 10GZR LR 2 5 dBm ...

Страница 42: ...Gigabit Ethernet SPA However the information in this document pertains only to SFP modules that plug into the 2 Port Gigabit Ethernet SPA ports See the SFP Module and Cabling Specifications for Gigabit Ethernet SPAs section on page 3 25 for SFP module options module specifications and cabling specifications For CWDM and DWDM SFP module specifications see the CWDM and DWDM SFP Modules for the Gigab...

Страница 43: ...he 2 Port Gigabit Ethernet SPA supports automatic MDI MDIX crossover at all speeds of operation allowing the SPA to work with straight through and crossover Ethernet cables 5 Port Gigabit Ethernet SPA Overview The following sections describe the 5 Port Gigabit Ethernet SPA 5 Port Gigabit Ethernet SPA LEDs page 3 21 5 Port Gigabit Ethernet SPA Connectors page 3 22 5 Port Gigabit Ethernet SPA LEDs T...

Страница 44: ...un every time an SFP module is inserted into the 5 Port Gigabit Ethernet SPA and only SFP modules that pass this check will be usable by the 5 Port Gigabit Ethernet SPA SFP modules exist for technologies other than Gigabit Ethernet and for products other than the 5 Port Gigabit Ethernet SPA However the information in this document pertains only to SFP modules that plug into the 5 Port Gigabit Ethe...

Страница 45: ...t SPA LEDs 8 Port Gigabit Ethernet SPA Connectors The 8 Port Gigabit Ethernet SPA has eight individual fiber optic receivers that support SFP modules Each port can send and receive traffic using the optical fiber connections SFP Module Connections The small form factor pluggable SFP module is an input output I O device that plugs into the Gigabit Ethernet ports on the 8 Port Gigabit Ethernet SPA l...

Страница 46: ...plug into the 8 Port Gigabit Ethernet SPA ports See the SFP Module and Cabling Specifications for Gigabit Ethernet SPAs section on page 3 25 for SFP module options module specifications and cabling specifications For CWDM and DWDM SFP module specifications see the CWDM and DWDM SFP Modules for the Gigabit Ethernet SPAs section on page 3 29 10 Port Gigabit Ethernet SPA Overview The following sectio...

Страница 47: ...heck will be usable by the 10 Port Gigabit Ethernet SPA SFP modules exist for technologies other than Gigabit Ethernet and for products other than the 10 Port Gigabit Ethernet SPA However the information in this document pertains only to SFP modules that plug into the 10 Port Gigabit Ethernet SPA ports See the SFP Module and Cabling Specifications for Gigabit Ethernet SPAs section on page 3 25 for...

Страница 48: ...h applications SFP GE Z Extended wavelength 1000BASE ZX Contains a Class 1 laser of 1550 nm for 1000BASE ZX extended wavelength applications SFP GE T Cisco 1000BASET SFP The 1000BASE T SFP module operates on standard Category 5 wiring of up to 328 feet 100 m link length GLC FE 100FX Cisco 1000BASE FX SFP The 1000BASE FX SFP module operates operates on ordinary multimode fiber optic MMF link spans ...

Страница 49: ...1000BASE ZX module does not operate correctly when coupled to multimode fiber and it is not intended to be used in environments in which multimode fiber is frequently used for example building backbones or horizontal cabling The 1000BASE ZX module is intended to be used as a Physical Medium Dependent PMD component for Gigabit Ethernet interfaces found on various switch and router products It opera...

Страница 50: ...he SFP GE S is 6 5 feet 2 m and the minimum link distance for the SFP GE Z is 6 2 miles 10 km with an 8 dB attenuator installed at each end of the link Without attenuators the minimum link distance for the SFP GE Z is 24 9 miles 40 km Table 3 23 SFP Module Port Cabling Specifications SFP Modules Wavelength nm Fiber Type Core Size micron Modal Bandwidth MHz km Maximum Cable Distance SFP GE S 850 MM...

Страница 51: ...dules Table 3 24 provides CWDM SFP module specifications for all Gigabit Ethernet SPAs using SFP modules but not those Gigabit Ethernet SPAs using XFP modules DWDM SFP Module Specifications Table 3 25 provides DWDM SFP module specifications Note The DWDM SFP modules are only supported on the following SPAs 2 Port Gigabit Ethernet SPA Table 3 24 CWDM SFP Module Specifications CWDM Product Number CW...

Страница 52: ...dule 100 GHz ITU grid 34 DWDM SFP 4851 1000BASE DWDM 1548 51 nm SFP module 100 GHz ITU grid 36 DWDM SFP 4772 1000BASE DWDM 1547 72 nm SFP module 100 GHz ITU grid 37 DWDM SFP 4692 1000BASE DWDM 1546 92 nm SFP module 100 GHz ITU grid 38 DWDM SFP 4612 1000BASE DWDM 1546 12 nm SFP module 100 GHz ITU grid 39 DWDM SFP 4453 1000BASE DWDM 1544 53 nm SFP module 100 GHz ITU grid 41 DWDM SFP 4373 1000BASE DW...

Страница 53: ...ibility with SIPs and modular optics see the SIP and SPA Compatibility section on page 1 2 The following sections describe the 2 Port and 4 Port OC 3c STM 1 POS SPA 2 Port and 4 Port OC 3c STM 1 POS SPA LEDs page 3 31 2 Port and 4 Port OC 3c STM 1 POS SPA Interface Specifications page 3 32 2 Port and 4 Port OC 3c STM 1 POS SPA Optical Transceiver Modules and Cables page 3 32 2 Port and 4 Port OC 3...

Страница 54: ... Optical Transceiver Modules and Cables The 2 Port and 4 Port OC 3c STM 1 POS SPA uses a small form factor pluggable SFP optical transceiver module installed in each port for SONET and SDH single mode and multimode optical fiber connection see Figure 3 23 Cisco qualifies the optics that are approved for use with its SPAs The 2 Port and 4 Port OC 3c STM 1 POS SPA supports the following types of opt...

Страница 55: ...ps OC 3c STM 1 optical fiber SONET STS 3c or SDH STM 1 Use a single mode optical fiber that has a modal field diameter of 8 7 0 5 microns Nominal diameter is approximately 10 125 microns For single mode and multimode optical fiber connections you can use either a duplex LC type cable see Figure 3 24 or two simplex LC type cables one for transmit TX and one for receive RX Use single mode for interm...

Страница 56: ...80 nm Cabling distance maximum OC 3 MM 2 km 1 2 miles OC 3 SR 2 km 1 2 miles OC 3 IR 1 15 km 9 3 miles OC 3 LR 1 40 km 24 8 miles OC 3 LR 2 80 km 49 7 miles Operating case temperature range OC 3 MM 23 to 185o F 5 to 85o C OC 3 SR 23 to 185o F 5 to 85o C OC 3 IR 1 23 to 185o F 5 to 85o C OC 3 LR 1 23 to 185o F 5 to 85o C OC 3 LR 2 23 to 185o F 5 to 85o C TX power OC 3 MM 19 to 14 dBm OC 3 SR 15 to ...

Страница 57: ...ort OC 48c STM 16 POS RPR SPA has five types of LEDs four LEDs for each port on the SPA and one STATUS LED as shown in Figure 3 25 Figure 3 25 2 Port OC 48c STM 16 POS RPR SPA Faceplate Table 3 28 describes the 2 Port and 4 Port OC 48c STM 16 POS RPR SPA LEDs 1 PTH Pass Through LED 4 ACT Active Loopback LED 2 PRT Protect LED 5 STATUS LED 3 CAR Carrier Alarm LED S T A T U S 0 1 SPA 2XOC48 POS RPR 1...

Страница 58: ...ical transceiver modules Single mode short reach SR SFP module SFP OC48 SR Single mode intermediate reach IR SFP module SFP OC48 IR1 Single mode long reach LR SFP module SFP OC48 LR2 Each port on the 2 Port and 4 Port OC 48c STM 16 POS RPR SPA has one duplex LC type receptacle For single mode optical fiber connections you can use either a duplex LC type cable see Figure 3 26 or two simplex LC type...

Страница 59: ...pecification Description Wavelength OC 48 SR 1266 nm to 1360 nm OC 48 IR 1 1260 nm to 1360 nm OC 48 LR 2 1500 nm to 1580 nm Cabling distance maximum OC 48 SR 2 km 1 2 miles OC 48 IR 1 15 km 9 3 miles OC 48 LR 2 80 km 49 7 miles Operating case temperature range OC 48 SR 23 to 158o F 5 to 70o C OC 48 IR 1 23 to 158o F 5 to 70o C OC 48 LR 2 23 to 158o F 5 to 70o C TX power OC 48 SR 10 to 3 dBm OC 48 ...

Страница 60: ...page 3 38 1 Port OC 12c STM 4 POS SPA Interface Specifications page 3 39 1 Port OC 12c STM 4 POS SPA SFP Optical Transceiver Modules and Cables page 3 39 1 Port OC 12c STM 4 POS SPA LEDs The 1 Port OC 12c STM 4 POS SPA has three types of LEDs two LEDs for each port on the SPA and one STATUS LED as shown in Figure 3 27 Figure 3 27 1 Port OC 12c STM 4 POS SPA Faceplate Table 3 30 describes the 1 Por...

Страница 61: ...6 Management Information Base for Network Management of TCP IP Based Internets RFC 1157 Simple Network Management Protocol SNMP RFC 1213 Management Information Base MIB for Network Management of TCP IP Based Internets MIB II 1 Port OC 12c STM 4 POS SPA SFP Optical Transceiver Modules and Cables The 1 Port OC 12c STM 4 POS SPA uses a small form factor pluggable SFP optical transceiver module instal...

Страница 62: ... optical fiber SONET STS 12c or SDH STM 4 Use a single mode optical fiber that has a modal field diameter of 8 7 0 5 microns Nominal diameter is approximately 10 125 microns For single mode and multimode optical fiber connections you can use either a duplex LC type cable see Figure 3 29 or two simplex LC type cables one for transmit TX and one for receive RX Use single mode for intermediate or lon...

Страница 63: ...e maximum OC 12 MM 0 5 km 0 3 miles OC 12 SR 2 km 1 2 miles OC 12 IR 1 15 km 9 3 miles OC 12 LR 1 40 km 24 8 miles OC 12 LR 2 80 km 49 7 miles Operating case temperature range OC 12 MM 23 to 185o F 5 to 85o C OC 12 SR 23 to 185o F 5 to 85o C OC 12 IR 1 23 to 185o F 5 to 85o C OC 12 LR 1 23 to 185o F 5 to 85o C OC 12 LR 2 23 to 185o F 5 to 85o C TX power OC 12 MM 20 to 14 dBm OC 12 SR 15 to 8 dBm O...

Страница 64: ...00 Series Aggregation Services Routers SIP and SPA Hardware Installation Guide OL 14126 03 Chapter 3 Overview Cisco ASR 1000 Series Aggregation Services Routers Shared Port Adapters 1 Port OC 12c STM 4 POS SPA Overview ...

Страница 65: ...pment You need the following tools and parts to install SIPs and SPAs If you need additional equipment contact a service representative for ordering information Shared port adapter interface processor SIP Shared port adapter SPA Number 1 Phillips screwdriver Number 2 Phillips screwdriver 3 16 inch flat blade screwdriver Your own electrostatic discharge ESD prevention equipment or the disposable gr...

Страница 66: ...en dient u op de hoogte te zijn van de standaard praktijken om ongelukken te voorkomen Gebruik het nummer van de verklaring onderaan de waarschuwing als u een vertaling van de waarschuwing die bij het apparaat wordt geleverd wilt raadplegen BEWAAR DEZE INSTRUCTIES Varoitus TÄRKEITÄ TURVALLISUUSOHJEITA Tämä varoitusmerkki merkitsee vaaraa Tilanne voi aiheuttaa ruumiillisia vammoja Ennen kuin käsitt...

Страница 67: ...ERHETSINSTRUKSJONER Dette advarselssymbolet betyr fare Du er i en situasjon som kan føre til skade på person Før du begynner å arbeide med noe av utstyret må du være oppmerksom på farene forbundet med elektriske kretser og kjenne til standardprosedyrer for å forhindre ulykker Bruk nummeret i slutten av hver advarsel for å finne oversettelsen i de oversatte sikkerhetsadvarslene som fulgte med denne...

Страница 68: ...R Denna varningssignal signalerar fara Du befinner dig i en situation som kan leda till personskada Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanliga förfaranden för att förebygga olyckor Använd det nummer som finns i slutet av varje varning för att hitta dess översättning i de översatta säkerhetsvarningar som medföljer denna anordning...

Страница 69: ...4 5 Cisco ASR 1000 Series Aggregation Services Routers SIP and SPA Hardware Installation Guide OL 14126 03 Chapter 4 Preparing to Install a SIP or a Shared Port Adapter Safety Guidelines ...

Страница 70: ...ctric shock do not connect safety extra low voltage SELV circuits to telephone network voltage TNV circuits LAN ports contain SELV circuits and WAN ports contain TNV circuits Some LAN and WAN ports both use RJ 45 connectors Use caution when connecting cables Statement 1021 Warning Hazardous network voltages are present in WAN ports regardless of whether power to the unit is OFF or ON To avoid elec...

Страница 71: ...ne jacks in wet locations unless the jack is specifically designed for wet locations Statement 1036 Warning Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface Statement 1037 Warning Avoid using a telephone other than a cordless type during an electrical storm There may be a remote risk of electric shock from lightning State...

Страница 72: ...ations Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface Use caution when installing or modifying telephone lines Preventing Electrostatic Discharge Damage Electrostatic discharge ESD damage which can occur when electronic cards or components are improperly handled results in complete or intermittent failures SIPs SPAs and...

Страница 73: ... ring Keep the transmit port covered whenever a cable is not connected to it Although multimode transceivers typically use LEDs for transmission it is good practice to keep open ports covered and avoid staring into open ports or apertures The single mode aperture port contains a laser warning label as shown in Figure 4 1 The multimode aperture contains a Class 1 LED warning label as shown in Figur...

Страница 74: ...4 10 Cisco ASR 1000 Series Aggregation Services Routers SIP and SPA Hardware Installation Guide OL 14126 03 Chapter 4 Preparing to Install a SIP or a Shared Port Adapter Laser LED Safety ...

Страница 75: ...SD damage See the Preventing Electrostatic Discharge Damage section on page 4 8 for ESD precautions Before you begin installation read Chapter 4 Preparing to Install a SIP or a Shared Port Adapter for a list of parts and tools required for installation Caution Always handle the SIP by the carrier edges and handle never touch the SIP components or connector pins See Figure 5 1 When a slot is not in...

Страница 76: ...n of a SPA page 5 7 Deactivation and Activation Configuration Examples page 5 7 Preparing for Online Removal of a SIP The Cisco ASR 1000 Series Routers support OIR of the SIP To do this you can power down a SIP which automatically deactivates any installed SPAs and remove the SIP with the SPAs still intact Although graceful deactivation of a SIP is preferred using the hw module slot stop command t...

Страница 77: ...he SPAs automatically reactivate with the new SIP To activate a SIP and its installed SPAs after the SIP has been deactivated use the following command in global configuration mode For more information about chassis slot numbering see the Identifying Slots and Subslots for SIPs and SPAs section on page 2 2 Verifying Deactivation and Activation of a SIP To verify the deactivation of a SIP enter the...

Страница 78: ...ASR1006 Slot Type State Insert time ago 0 ASR1000 SIP10 ok 03 19 46 0 0 SPA 5X1GE V2 ok 03 18 28 0 1 SPA 8X1FE TX V2 ok 03 18 28 0 2 SPA 2XCT3 DS0 ok 03 18 19 1 ASR1000 SIP10 ok 03 19 46 1 0 SPA 2XOC3 POS ok 03 18 28 1 1 SPA 8XCHT1 E1 ok 03 18 28 1 2 SPA 2XT3 E3 ok 03 18 18 R0 ASR1000 RP1 ok active 03 19 46 F0 ASR1000 ESP10 ok active 03 19 46 P0 ASR1006 PWR AC ok 03 19 14 P1 ASR1006 FAN ok 03 19 1...

Страница 79: ... with the SPA in preparation for OIR In similar fashion you do not need to independently restart any interfaces on a SPA after OIR of a SPA or SIP Choosing the Mode of the hw module subslot Command You can deactivate a SPA and all of its interfaces by using the hw module subslot command in one of two modes If you choose to use the hw module subslot shutdown command in global configuration mode you...

Страница 80: ... reactivate the SPA and its interfaces Command Purpose Router config hw module subslot slot number subslot number shutdown powered unpowered Deactivates the SPA in the specified slot and subslot of the SIP where slot number Specifies the chassis slot number where the SIP is installed subslot number Specifies the subslot number on a SIP where a SPA is installed shutdown Shuts down the specified SPA...

Страница 81: ...rify activation and proper operation of a SPA enter the show hw module subslot all oir command and observe ok in the Operational Status field as shown in the following example Router show hw module subslot all oir Module Model Operational Status subslot 2 0 SPA 1X10GE L V2 ok subslot 2 1 SPA 8X1GE v2 ok Deactivation and Activation Configuration Examples This section provides the following examples...

Страница 82: ...emoves power to the SPA Router config hw module subslot 1 0 shutdown unpowered Activation of a SPA Configuration Example Activate a SPA if you have previously deactivated it If you have not deactivated a SPA and its interfaces during OIR of a SIP then the SPA is automatically reactivated upon reactivation of the SIP The following example activates the SPA that is installed in subslot 0 of the SIP ...

Страница 83: ...umbscrews on both sides of the SIP Step 5 Connect all cables to each SPA To remove a SIP refer to Figure 5 2 and do the following Step 1 To remove the SIP first disconnect all cables from each SPA Step 2 Loosen the locking thumbscrews on both sides of the SIP Step 3 Slide the SIP out of the router slot If you are removing a blank filler plate pull the blank filler plate completely out of the route...

Страница 84: ...2 SIP Installation and Removal 231540 0 3 1 ASR1000 SIP10G 2 0 3 1 ASR1000 SIP10 PWR STATUS ASR1000 SIP10G 2 0 3 1 ASR1000 SIP10 PWR STATUS ASR1000 SIP10G 0 3 1 ASR1000 SIP10G 2 0 3 1 ASR1000 SIP10 PWR STATUS ASR1000 SIP10G 0 3 1 ASR1000 SIP10G 2 0 3 1 ASR1000 SIP10 PWR STATUS ASR1000 SIP10G 0 3 1 ASR1000 SIP10G 2 0 3 1 ASR1000 SIP10 PWR STATUS ASR1000 SIP10G 2 0 ASR1000 SIP10G 2 0 3 1 ASR1000 SIP...

Страница 85: ...t board is mounted to a metal carrier and is sensitive to electrostatic discharge ESD damage See the Preventing Electrostatic Discharge Damage section on page 4 8 for ESD precautions Before you begin installation read Chapter 4 Preparing to Install a SIP or a Shared Port Adapter for a list of parts and tools required for installation Caution Always handle the SPA by the carrier edges and handle ne...

Страница 86: ...ions for installing and removing a SPA in a SIP Caution When performing the following procedures wear a grounding wrist strap to avoid ESD damage to the SPA Some platforms have an ESD connector for attaching the wrist strap Do not directly touch the midplane or backplane with your hand or any metal tool See Preventing Electrostatic Discharge Damage page 4 8 for information about ESD Figure 6 2 ill...

Страница 87: ...ght be slightly behind the SIP faceplate Step 3 After the SPA is properly seated fasten the SPA in place with the captive installation screws on either side of the SPA Removing a SPA from a SIP To remove a SPA from a SIP refer to Figure 6 2 and do the following Step 1 If attached remove any cables from the SPA Step 2 To remove the SPA from the SIP unfasten the captive installation screws on either...

Страница 88: ...before making fiber optic connections Cleaning Optical Devices See the Inspection and Cleaning Procedures for Fiber Optic Connections and the Compressed Air Cleaning Issues for Fiber Optic Connections documents for information on cleaning optical devices Checking the Installation This section describes the procedures you can use to verify the SIP and SPA installation and includes information on th...

Страница 89: ...as not been previously installed in the same slot or subslot then the configuration for all associated interfaces will be empty Note New interfaces are not available until you configure them Step 2 If the SIPs and SPAs have not become active within three minutes refer to the system console messages as follows If a SIP or SPA is undergoing a field programmable device FPD upgrade then console messag...

Страница 90: ...talled in the empty subslot to allow the router or switch to conform to electromagnetic interference EMI emissions requirements and to allow proper airflow across the SPAs If you plan to install a new SPA in a subslot that is not in use you must first remove the SPA blank filler plate Table 6 1 show Commands to Display SPA Information Command Type of Information Provided show controllers type slot...

Страница 91: ...SPA as well as cable routing Figure 6 3 SPA Cable Management Brackets To install cable management brackets on a SPA perform the following steps Step 1 Screw the two pull assemblies into both sides of the SPA Step 2 Insert the cable management bracket into the slot Step 3 To remove the cable management bracket depress the button on the bracket and pull it out Note Blank filler plugs are provided if...

Страница 92: ...6 8 Cisco ASR 1000 Series Aggregation Services Routers SIP and SPA Hardware Installation Guide OL 14126 03 Chapter 6 Installing and Removing a Shared Port Adapter SPA Cable Management Brackets ...

Страница 93: ...is section describes troubleshooting the installation of the SIPs and SPAs Possible problems observations and comments and solutions are indicated for the following troubleshooting symptoms SIP transitions repeatedly from on to off SIP is deactivated SIP Transitions Repeatedly from On to Off Possible Problem Observations and Comments Solutions SIP is booting up this is normal operation SIP STATUS ...

Страница 94: ... this procedure Remove the SPA from the SIP Inspect the SIP and the SPA Verify there are no bent pins or parts and that there is nothing lodged in the two devices that could prevent a good connection Insert the SPA in the SIP by sliding the SPA all the way into the SIP until the SPA is firmly seated in the SPA interface connector When fully seated in the SIP the SPA might be slightly behind the SI...

Страница 95: ...tic Discharge Damage page 4 8 for information about preventing ESD Note These instructions assume that the SPA and cable management brackets have been removed from the router according to the recommended procedures specified in this guide To pack a SPA for shipment see Figure 7 1 and perform the following steps Step 1 Open the clamshell container and place the SPA into the appropriate cavity Cauti...

Страница 96: ...n Services Routers SIP and SPA Hardware Installation Guide OL 14126 03 Chapter 7 Troubleshooting the Installation Packing a SPA for Shipment Figure 7 1 Packing a SPA for Shipment 204356 1 2 3 2 1 Clamshell 2 Cushion foam 3 Exterior carton ...

Страница 97: ... this procedure wear grounding wrist straps to avoid ESD damage to the card See Preventing Electrostatic Discharge Damage page 4 8 for information about preventing ESD Note These instructions assume that the SIP has been removed from the router according to the recommended procedures specified in this guide To pack a SIP for shipment see Figure 7 2 and perform the following steps Step 1 Insert the...

Страница 98: ...ware Installation Guide OL 14126 03 Chapter 7 Troubleshooting the Installation Packing a SIP for Shipment Figure 7 2 Packing a SIP for Shipment 4 1 2 3 5 4 204357 1 Corrugated spacer 2 Bottom support for inner carton 3 Inner carton 4 Foam packing cushions 5 Exterior carton ...

Страница 99: ...s and connectors 3 3 interface specifications 3 3 LEDs 3 2 2 Port and 4 Port OC 3c STM 1 POS SPA interface specifications 3 32 LEDs 3 31 optical transceiver modules and cables 3 32 2 Port and 4 Port OC 48c STM 16 POS RPR SPA cables optical transceiver modules connectors 3 36 interface specifications 3 36 LEDs 3 35 2 Port and 4 Port OC 48c STM 16 POS RPR SPA 2 Port Gigabit Ethernet SPA cables and c...

Страница 100: ...w module slot start command 5 8 hw module slot stop command 5 2 5 3 hw module sublsot start stop reload command 5 3 hw module subslot shutdown command 5 6 5 7 5 8 I interface processor tools and parts required for installation 4 1 intermediate reach SFP optical transceiver module 3 32 3 36 3 39 L LEDs on SIPs 2 5 long reach optical transceiver module 3 39 SFP optical transceiver module 3 32 3 36 M...

Страница 101: ...ased Internets 3 39 RFC 1619 PPP over SONET SDH 3 39 RFC 1662 PPP in HDLC like Framing 3 39 RFC 2615 PPP over SONET SDH 3 32 S safety guidelines 4 1 SFP small form factor pluggable optics figure 3 33 3 40 2 Port Gigabit Ethernet SPA 3 20 Cisco qualification check 1 3 for OC 12c STM 4 POS SPA 3 38 3 39 for OC 3c STM 1 POS SPA 3 31 3 32 for OC 48c STM 16 POS RPR SPA 3 36 qualified for SPAs table 1 4...

Страница 102: ...handling 6 1 installing 6 3 interfaces 1 2 optics compatibility table 1 4 1 5 1 6 reactivating 5 6 removal 5 4 6 1 single height description 1 2 SIP compatibility table 1 2 1 3 subslot numbering figure 2 3 SPA interface processors SIPs 2 1 subslots description 1 1 numbering 2 4 specifying location in CLI 2 4 T troubleshooting the installation 7 1 U using show commands to verify SIP and SPA status ...