• Enable the programmable softkeys (PSK) and add the ACD softkeys to the softkey list. For more
information, see
Configuring Programmable Softkeys, on page 171
.
• Check the phone configuration to determine if
BroadSoft ACD
is set to yes.
Call Doesn't Record
Problem
When a user tries to record a call, the recording doesn't takes place.
Cause
This is often due to configuration issues.
Solution
1.
Set the phone to always record a call.
2.
Make a call.
If the recording doesn't start, there are configuration problems. Check the configuration of the BroadWorks
and third-party recorder.
If the recording does start:
1.
Set the phone to record on demand.
2.
Set up Wireshark to capture a trace of the network traffic between the phone and Broadworks when the
problem occurs. When you have the trace, contact TAC for further assistance.
An Emergency Call Doesn't Connect to Emergency Services
Problem
A user tries to place an emergency call, but the call doesn't connect to the emergency services (fire, police,
or emergency services operator).
Solution
Check the emergency call configuration:
• Company Identifier or location request URL setup is incorrect. See
Configure a Phone to Make Emergency
.
• An incorrect or blank emergency number exists in the Dial Plan setup. See
The location request servers (emergency call service provider) did not respond with a phone location, after
multiple attempts.
Cisco IP Phone 7800 Series Multiplatform Phones Administration Guide
313
Cisco IP Phone Troubleshooting
Call Doesn't Record
Содержание 7821
Страница 23: ...P A R T I About the Cisco IP Phone Technical Details on page 11 Cisco IP Phone Hardware on page 21 ...
Страница 24: ......
Страница 46: ......
Страница 99: ...P A R T III Hardware and Accessory Installation Cisco IP Phone Accessories on page 87 Wall Mounts on page 91 ...
Страница 100: ......
Страница 132: ......
Страница 218: ......