2-880
Catalyst 3750 Switch Command Reference
OL-8552-07
Chapter 2 Catalyst 3750 Switch Cisco IOS Commands
udld port
udld port
Use the
udld
port
interface configuration command to enable the UniDirectional Link Detection
(UDLD) on an individual interface or prevent a fiber-optic interface from being enabled by the
udld
global configuration command. Use the
no
form of this command to return to the
udld
global
configuration command setting or to disable UDLD if entered for a nonfiber-optic port.
udld port
[
aggressive
]
no udld port
[
aggressive
]
Syntax Description
Defaults
On fiber-optic interfaces, UDLD is not enabled, not in aggressive mode, and not disabled. For this
reason, fiber-optic interfaces enable UDLD according to the state of the
udld enable
or
udld aggressive
global configuration command.
On nonfiber-optic interfaces, UDLD is disabled.
Command Modes
Interface configuration
Command History
Usage Guidelines
A UDLD-capable port cannot detect a unidirectional link if it is connected to a UDLD-incapable port of
another switch.
UDLD supports two modes of operation: normal (the default) and aggressive. In normal mode, UDLD
detects unidirectional links due to misconnected interfaces on fiber-optic connections. In aggressive
mode, UDLD also detects unidirectional links due to one-way traffic on fiber-optic and twisted-pair
links and due to misconnected interfaces on fiber-optic links. For information about normal and
aggressive modes, see the “Configuring UDLD” chapter in the software configuration guide for this
release.
To enable UDLD in normal mode, use the
udld port
interface configuration command. To enable UDLD
in aggressive mode, use the
udld port
aggressive
interface configuration command.
Use the
no udld port
command on fiber-optic ports to return control of UDLD to the
udld enable
global
configuration command or to disable UDLD on nonfiber-optic ports.
Use the
udld port aggressive
command on fiber-optic ports to override the setting of the
udld enable
or
udld aggressive
global configuration command. Use the
no
form on fiber-optic ports to remove this
setting and to return control of UDLD enabling to the
udld
global configuration command or to disable
UDLD on nonfiber-optic ports.
aggressive
Enable UDLD in aggressive mode on the specified interface.
Release
Modification
12.1(11)AX
This command was introduced.
12.2(20)SE
The
disable
keyword was removed.
Содержание 3750 - Catalyst EMI Switch
Страница 494: ...2 464 Catalyst 3750 Switch Command Reference OL 8552 07 Chapter 2 Catalyst 3750 Switch Cisco IOS Commands reserved only ...
Страница 772: ...2 742 Catalyst 3750 Switch Command Reference OL 8552 07 Chapter 2 Catalyst 3750 Switch Cisco IOS Commands show vtp ...
Страница 1132: ...D 2 Catalyst 3750 Switch Command Reference OL 8552 07 Appendix D Acknowledgments for Open Source Software ...