12-26
Catalyst 2975 Switch Software Configuration Guide
OL-19720-02
Chapter 12 Configuring Interface Characteristics
Configuring Ethernet Interfaces
For information about the output of the
show power inline consumption
privileged EXEC command,
see the command reference for this release.
Configuring Power Policing
By default, the switch monitors the real-time power consumption of connected powered devices. You
can configure the switch to police the power usage. By default, policing is disabled.
For more information about the cutoff power value, the power consumption values that the switch uses,
and the actual power consumption value of the connected device, see the “Power Monitoring and Power
Policing” section.
Beginning in privileged EXEC mode, follow these steps to enable policing of the real-time power
consumption of a powered device connected to a PoE port:
Command
Purpose
Step 1
configure terminal
Enter global configuration mode.
Step 2
interface
interface-id
Specify the physical port to be configured, and enter interface
configuration mode.
Step 3
power inline police
[
action log
]
If the real-time power consumption exceeds the maximum power
allocation on the port, configure the switch to take one of these actions:
•
Shut down the PoE port, turn off power to it, and put it in the
error-dsabled state—Enter the
power inline police
command.
Note
You can enable error detection for the PoE error-disabled cause
by using the
errdisable detect cause inline-power
global
configuration command. You can also enable the timer to recover
from the PoE error-disabled state by using the
errdisable
recovery cause inline-power
interval
interval
global
configuration command.
•
Generate a syslog message while still providing power to the
port—Enter the
power inline police
action log
command.
If you do not enter the
action log
keywords, the default action shuts down
the port and puts the port in the error-disabled state.
Step 4
exit
Return to global configuration mode.
Step 5
errdisable detect cause inline-power
and
errdisable recovery cause inline-power
and
errdisable recovery interval
interval
(Optional) Enable error recovery from the PoE error-disabled state, and
configure the PoE recover mechanism variables.
For
interval
interval
, specify the time in seconds to recover from the
error-disabled state. The range is 30 to 86400.
By default, the recovery interval is 300 seconds.
Step 6
exit
Return to privileged EXEC mode.
Step 7
show power inline police
show errdisable recovery
Display the power monitoring status, and verify the error recovery
settings.
Step 8
copy running-config startup-config
(Optional) Save your entries in the configuration file.
Содержание 2975 - Catalyst LAN Base Switch
Страница 36: ...Contents xxxvi Catalyst 2975 Switch Software Configuration Guide OL 19720 02 ...
Страница 40: ...xxxviii Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Preface ...
Страница 62: ...1 22 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 1 Overview Where to Go Next ...
Страница 398: ...13 30 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 13 Configuring VLANs Configuring VMPS ...
Страница 424: ...15 18 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 15 Configuring VTP Monitoring VTP ...
Страница 628: ...26 8 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 26 Configuring UDLD Displaying UDLD Status ...
Страница 660: ...28 8 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 28 Configuring RMON Displaying RMON Status ...
Страница 888: ...38 32 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 38 Troubleshooting Troubleshooting Tables ...