12-17
Catalyst 2975 Switch Software Configuration Guide
OL-19720-02
Chapter 12 Configuring Interface Characteristics
Configuring Ethernet Interfaces
Setting the Type of a Dual-Purpose Uplink Port
Some switches support dual-purpose uplink ports. By default, the switch dynamically selects the
interface type that first links up. However, you can use the
media-type
interface configuration command
to manually select the RJ-45 connector or the SFP module connector. For more information, see the
“Dual-Purpose Uplink Ports” section on page 12-4
.
Beginning in privileged EXEC mode, follow these steps to select which dual-purpose uplink to activate so
that you can set the speed and duplex. This procedure is optional.
Port blocking (unknown multicast
and unknown unicast traffic)
Disabled (not blocked). See the
Broadcast, multicast, and unicast
storm control
Disabled. See the
“Default Storm Control Configuration” section
.
Protected port
Disabled. See the
“Configuring Protected Ports” section on
Port security
Disabled. See the
“Default Port Security Configuration” section
Port Fast
Disabled. See the
“Default Optional Spanning-Tree
Configuration” section on page 18-12
.
Auto-MDIX
Enabled.
Note
The switch might not support a pre-standard powered
device—such as Cisco IP phones and access points that do
not fully support IEEE 802.3af—if that powered device is
connected to the switch through a crossover cable. This is
regardless of whether auto-MIDX is enabled on the switch
port.
Power over Ethernet (PoE)
Enabled (auto).
Keepalive messages
Disabled on SFP module ports; enabled on all other ports.
Table 12-2
Default Layer 2 Ethernet Interface Configuration (continued)
Feature
Default Setting
Command
Purpose
Step 1
configure terminal
Enter global configuration mode.
Step 2
interface
interface-id
Specify the dual-purpose uplink port to be configured, and enter
interface configuration mode.
Содержание 2975 - Catalyst LAN Base Switch
Страница 36: ...Contents xxxvi Catalyst 2975 Switch Software Configuration Guide OL 19720 02 ...
Страница 40: ...xxxviii Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Preface ...
Страница 62: ...1 22 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 1 Overview Where to Go Next ...
Страница 398: ...13 30 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 13 Configuring VLANs Configuring VMPS ...
Страница 424: ...15 18 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 15 Configuring VTP Monitoring VTP ...
Страница 628: ...26 8 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 26 Configuring UDLD Displaying UDLD Status ...
Страница 660: ...28 8 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 28 Configuring RMON Displaying RMON Status ...
Страница 888: ...38 32 Catalyst 2975 Switch Software Configuration Guide OL 19720 02 Chapter 38 Troubleshooting Troubleshooting Tables ...