Chapter 6 Router Field Diagnostics
diag Command Output Examples
6-16
Cisco 12010, Cisco 12410, and Cisco 12810 Router Installation and Configuration Guide
OL-11496-01
FDIAG_STAT_IN_PROGRESS(7): test #25 TBM to RX SOP Packet - 4302
Terminal Loopback
FDIAG_STAT_IN_PROGRESS(7): test #26 TBM to RX SOP Packet - Framer
System Bus Loop
FDIAG_STAT_IN_PROGRESS(7): test #27 RBM to TBM Fabric Packet Loopback
FDIAG_STAT_IN_PROGRESS(7): test #28 TBM to RBM Packet, RBM page
crossing
FDIAG_STAT_IN_PROGRESS(7): test #29 TBM to TX SOP Packet Simultaneous
FDIAG_STAT_IN_PROGRESS(7): test #30 TBM to PSA Multicast Packets -
Framer Loopbac
FDIAG_STAT_DONE(7)
FD 7> Changed current_status to FDIAG_STAT_IDLE
Field Diagnostic ****PASSED**** for slot 7
Field Diag eeprom values: run 62 fail mode 0 (PASS) slot 7
last test failed was 0, error code 0
Shutting down diags in slot 7
Board will reload
Displaying Previous Test Results
The following example shows the previous test results of a line card in slot 7.
Diagnostics had been run 64 times on this line card. Because the board PASSED
the last field diagnostics session, the fail mode was 0, and the last test that failed
was 0.
Router #
diag 7 prev
Field Diag eeprom values: run 64 fail mode 0 (PASS) slot 7
last test failed was 0, error code 0