Troubleshooting the Cisco RPS B-5
Reading Error Messages on Cisco 2600 and 3600 Series Routers
Reading Error Messages on Cisco 2600 and 3600 Series
Routers
When Cisco RPS status failure is detected while connected to Cisco 2600 and 3600 series
routers, Cisco IOS software receives an interrupt and displays the error messages on the
router console. Table B-2 describes these error messages:
•
Console error message
•
RPS LED status
•
Description of the error
•
SNMP trap issued from the error
•
Solution to the error
•
Console message issued after correcting the error
•
SNMP trap issued after correcting the error
Table B-2
Error Descriptions and LED Status
RPS LED Status
Condition
Error Indicators, Descriptions, and Solutions
DC LED 1, 2, 3, or 4 is
amber.
Note
The DC FAIL
LED is amber for 10 to 15
seconds after the DC
output module has been
connected and the
external device has been
powered on.
FAIL
Console Error Message:
When an external device console monitor screen displays the Cisco IOS
software prompt (routername > or routername #)
“System detected
Redundant Power Supply DC FAIL condition.”
The Cisco IOS software checks the condition once every 30 seconds. If
the condition still exists, the error message redisplays.
When an external device console monitor screen displays the ROMMON
prompt (rommon #>)
“*** System Environmental Interrupt ***
WARNING: REDUNDANT POWER SUPPLY DC FAIL BIT IS
ASSERTED.”
rpsappb Page 5 Monday, September 14, 1998 8:19 AM