5 pins TRIGGER_IN Circuit
Trigger signals can be input directly into the camera. When to use this terminal, set TriggerSource of AcquisitionControl to
LineIn. Please refer to 7. Camera Operation Mode for the details.
・
5.0V, 3.3V CMOS level input (TTL compatible)
・
Input voltage Low: 0.5Vdc(Min), High: 2.1Vdc(Max)
6
How to Save and Initialize the Setting
UserSets
UserSetSave
(Execute)
UserSetDefault
(Execute)
If you wish to initialize the setting values, execute UserSetDefault. Execution is only valid at Link rate (CxpLinkConfiguration)
CXP-1. However, as long as you do not execute UserSetSave, the setting values will not be saved. If you wish to save the
setting values, execute UserSetSave. Setting values will be saved to the memory in the camera and will operate with the saved
settings at next start-up.
+5.0V
HD74LV1GT32ACME
1
2
3
4
5
SIGNAL_OUT
(CAMERA_INTERNAL)
HD74LV1GT14ACME
1
2
3
5
4
100
1K
+5.0V
(CAMERA_INTERNAL)
TRRIGER_IN