VCC-5CXP3R
Rev. 905-0052-00
©2016 CIS Corporation. All rights reserved.
23
(2) Pulse Width Control
TRIG IN
Video Out
Effective Line
Exposure
Effective Line
①
FVAL Out
Sequence Control Start
Sequence Control Finish
Effective Line
Effective Line
②
Effective Line
Effective Line
Effective Line
When TriggerSelectorAndActivation is set to FrameStartLevelHigh orFrameStartLevelLow, sequence will start
when the trigger is ON.
・
Pulse width shall correspond to exposure time (
①
,
②
) for each frame.
・
Sequence performance will end after the sequence loop count of image output. After that, the performance will
stop.
9.4
Burst Mode
Edge control which uses trigger signal, level control, and register start is selectable for the start and hold of
sequence.
・
Please set TriggerSelectorAndActivation to FrameBurstStart.
(1) Edge Control
TRIG IN
Video Out
Effective Line
Exposure
Effective Line
①
FVAL Out
②
Sequence Control Start
Sequence Control Finish
Effective Line
Effective Line
Effective Line
①
When TriggerSelectorAndActivation is set to FrameBurstStartEdge, sequence will start when the trigger is ON.
・
The exposure time (
①
) and output frame time (
②
) for each frame shall be controlled by sequence parameter set
and image size which are set beforehand.
・
Sequence performance will end after the completion of sequence loop count of image output. After that, the
performance will stop.
Aegis Electronic Group, Inc.