VCC-2CXP6R
Rev.905-0187-02
©2019 CIS Corporation. All rights reserved.
7
4.
Output Timing
4.1.
Horizontal Sync. Timing
LVAL Out
~ ~
Effective Data
H blank
Sensor Operation CLK : 74.25MHz
Video Out
~ ~
※ The time for 1H shall be changed depends on the link rate and video output format.
※ The blanking pixel number for 1H shall be changed depends on the link rate and video output format.
Effective pixel numbers and blanking pixel numbers
Video output
Format
CXP-3
BayerRG/Mono8
204
268
472
6.36
BayerRG/Mono10 204
376
580
7.81
BayerRG/Mono12 204
480
684
9.21
CXP-6
BayerRG/Mono8
204
32
236
3.18
BayerRG/Mono10 204
86
290
3.91
BayerRG/Mono12 204
138
342
4.61
Sensor Operation clk
74.25 MHz
Link rate
Effective
Data
H blank
1H total pixel
number
Time for 1H
[us]