Cirrus Design
Section 3
SR22T
Emergency Procedures
P/N 13772-005
3-31
P/N 13772-005
3-31
Fuel System Emergencies
Low Fuel Quantity
FUEL QTY Warning
1. Fuel Quantity Gages.......................................................... CHECK
If fuel quantity indicates less than or equal to 9 gallons:
a. Land as soon as practical.
If fuel quantity indicates more than 9 gallons:
a. Flight................................................... CONTINUE, MONITOR
Amplification
Annunciation indicates fuel totalizer quantity is less than or equal to 9
gallons.
Fuel Imbalance
FUEL IMBALANCE Warning
1. Fuel Quantity Gages.......................................................... CHECK
2. Fuel Pump ......................................................................... BOOST
If HIGH BOOST already in use for vapor suppression, pump
should be left in this position for tank switch.
3. Fuel Selector.......................................... SELECT FULLEST TANK
4. Fuel Pump ............................................................. AS REQUIRED
After switching tanks, message will remain until sensed
imbalance is less than 12 gallons.
Amplification
Fuel level imbalance (between left and right) is greater than 12
gallons.
FUEL QTY
FUEL IMBALANCE
Original Issue
Содержание SR22T
Страница 14: ...1 2 P N 13772 005 Section 1 Cirrus Design General SR22T Original Issue Intentionally Left Blank...
Страница 56: ...2 30 P N 13772 005 Section 2 Cirrus Design Limitations SR22T Original Issue Intentionally Left Blank...
Страница 102: ...3 46 P N 13772 005 Section 3 Cirrus Design Emergency Procedures SR22T Original Issue Intentionally Left Blank...
Страница 128: ...4 2 P N 13772 005 Section 4 Cirrus Design Normal Procedures SR22T Original Issue Intentionally Left Blank...
Страница 158: ...4 32 P N 13772 005 Section 4 Cirrus Design Normal Procedures SR22T Original Issue Intentionally Left Blank...
Страница 160: ...5 2 P N 13772 005 Section 5 Cirrus Design Performance Data SR22T Original Issue Intentionally Left Blank...
Страница 194: ...6 2 P N 13772 005 Section 6 Cirrus Design Weight and Balance Data SR22T Original Issue Intentionally Left Blank...
Страница 206: ...6 14 P N 13772 005 Section 6 Cirrus Design Weight and Balance Data SR22T Original Issue Intentionally Left Blank...
Страница 210: ...7 4 P N 13772 005 Section 7 Cirrus Design Systems Description SR22T Original Issue Intentionally Left Blank...
Страница 302: ...8 2 P N 13772 005 Section 8 Cirrus Design Handling and Servicing SR22T Original Issue Intentionally Left Blank...
Страница 334: ...8 34 P N 13772 005 Section 8 Cirrus Design Handling and Servicing SR22T Original Issue Intentionally Left Blank...
Страница 366: ...8 of 8 P N 13772 131 Section 9 Cirrus Design Supplements SR22 SR22T Revision 02 01 06 10 Intentionally Left Blank...
Страница 402: ...6 of 6 P N 13772 136 Section 9 Cirrus Design Supplements SR22 SR22T Revision 01 01 06 10 Intentionally Left Blank...
Страница 412: ...4 of 4 P N 13772 146 Section 9 Cirrus Design Supplements SR22T Original Issue 11 16 2010 Intentionally Left Blank...
Страница 494: ...52 of 52 P N 13772 151 Section 9 Cirrus Design Supplements SR22T Original Issue 02 01 13 Intentionally Left Blank...
Страница 496: ...10 2 P N 13772 005 Section 10 Cirrus Design Safety Information SR22T Original Issue Intentionally Left Blank...