Cirrus Design
Section 3
SR22T
Emergency Procedures
P/N 13772-005
3-27
P/N 13772-005
3-27
Overboost / Pressure Relief Valve
1. Power Lever ....................................REDUCE to 30.5 in.Hg or less
2. Mixture ..................................ADJUST fuel flow to top of green arc
If continued surging is present:
3. Land as soon as practical.
Amplification
Although it is an unlikely failure mode, the wastegate may be stuck in a
closed position. If pressure relief valve is obviously surging (cycling
high manifold pressure followed by sudden drop to lesser pressure,
may be accompanied by "pop" noise), it may be evidence of MAP
controller setting problem but may also be evidence of a seized
wastegate. Engine will be adequately protected by the pressure relief
valve, but turbo overspeed may result in turbo failure if pressure relief
valve remains OPEN. Reducing manifold pressure (via power lever)
will decrease the airflow through the engine, thereby reducing the
energy available to drive the turbine; enriching the mixture will
maintain lower turbine temperatures. It is unnecessary to descend
prematurely, lower altitudes (higher density air) may aggravate the
condition.
Turbine Inlet Temperature High
TIT Warning
1. Mixture ............................. ADJUST Fuel Flow to Top of Green Arc
2. Ignition Switch.....................................................CHECK on BOTH
If TIT remains in excess of limits:
a. Power ........................................................................REDUCE
b. Land as soon as practical.
Amplification
Annunciation indicates that one or both turbochargers are exceeding
turbine inlet temperature limits, condition can be reduced and
controlled by mixture management but may be a sign of improper
combustion or magneto failure.
TIT
Original Issue
Содержание SR22T
Страница 14: ...1 2 P N 13772 005 Section 1 Cirrus Design General SR22T Original Issue Intentionally Left Blank...
Страница 56: ...2 30 P N 13772 005 Section 2 Cirrus Design Limitations SR22T Original Issue Intentionally Left Blank...
Страница 102: ...3 46 P N 13772 005 Section 3 Cirrus Design Emergency Procedures SR22T Original Issue Intentionally Left Blank...
Страница 128: ...4 2 P N 13772 005 Section 4 Cirrus Design Normal Procedures SR22T Original Issue Intentionally Left Blank...
Страница 158: ...4 32 P N 13772 005 Section 4 Cirrus Design Normal Procedures SR22T Original Issue Intentionally Left Blank...
Страница 160: ...5 2 P N 13772 005 Section 5 Cirrus Design Performance Data SR22T Original Issue Intentionally Left Blank...
Страница 194: ...6 2 P N 13772 005 Section 6 Cirrus Design Weight and Balance Data SR22T Original Issue Intentionally Left Blank...
Страница 206: ...6 14 P N 13772 005 Section 6 Cirrus Design Weight and Balance Data SR22T Original Issue Intentionally Left Blank...
Страница 210: ...7 4 P N 13772 005 Section 7 Cirrus Design Systems Description SR22T Original Issue Intentionally Left Blank...
Страница 302: ...8 2 P N 13772 005 Section 8 Cirrus Design Handling and Servicing SR22T Original Issue Intentionally Left Blank...
Страница 334: ...8 34 P N 13772 005 Section 8 Cirrus Design Handling and Servicing SR22T Original Issue Intentionally Left Blank...
Страница 366: ...8 of 8 P N 13772 131 Section 9 Cirrus Design Supplements SR22 SR22T Revision 02 01 06 10 Intentionally Left Blank...
Страница 402: ...6 of 6 P N 13772 136 Section 9 Cirrus Design Supplements SR22 SR22T Revision 01 01 06 10 Intentionally Left Blank...
Страница 412: ...4 of 4 P N 13772 146 Section 9 Cirrus Design Supplements SR22T Original Issue 11 16 2010 Intentionally Left Blank...
Страница 494: ...52 of 52 P N 13772 151 Section 9 Cirrus Design Supplements SR22T Original Issue 02 01 13 Intentionally Left Blank...
Страница 496: ...10 2 P N 13772 005 Section 10 Cirrus Design Safety Information SR22T Original Issue Intentionally Left Blank...