94
DS726PP2
CS4525
9.22.3
Under Voltage / Thermal Error State (UVTE[1:0])
Function:
Indicates the operational status of the amplifier. These bits can identify a Thermal Warning condition, a
Thermal Error condition, or an Under Voltage condition. The thresholds for each of these conditions is
listed in the
PWM Power Output Characteristics
table on
9.23
Device I.D. and Revision (Address 63h) - Read Only
9.23.1
Device Identification (DeviceID[4:0])
Default =11111
Function:
Identification code for the CS4525.
9.23.2
Device Revision (RevID[2:0])
Function:
Identifies the CS4525 device revision.
UVTE[1:0] Setting
Under Voltage & Thermal Error Status
00 ........................................ The device is operating normally.
01 ........................................ The device is operating normally; however a Thermal Warning condition is being reported.
10 ........................................ An Under Voltage condition is currently present.
11......................................... A Thermal Error condition is currently present.
7
6
5
4
3
2
1
0
DeviceID4
DeviceID3
DeviceID2
DeviceID1
DeviceID0
RevID2
RevID1
RevID0
DeviceID[4:0] Setting
Device ID Notes
11111.................................... Permanent device identification code.
RevID[2:0] Setting
Device Revision
000 ...................................... Revision A0 and B0.
010 ...................................... Revision C0.