Cirris Easy-Touch Pro Скачать руководство пользователя страница 1

Easy-Touch

 Pro

User Manual

Содержание Easy-Touch Pro

Страница 1: ...Easy Touch Pro User Manual ...

Страница 2: ......

Страница 3: ...dapter Sizes 18 2 4 Installing Adapters 19 2 5 Removing Adapters 20 2 6 Duplicating the Adapter Setup 21 2 7 Adapter Signatures 21 2 8 Cable Signatures 21 3 Cirris Easy Wire Software 23 3 1 Creating Default Adapters 23 3 2 Learning a Sample Cable 25 3 3 Verifying Editing the Test Program 26 3 4 Testing the Device Under Test 27 3 5 Accessing the Easy Wire Manual Help System 28 3 6 Sharing Wirelists...

Страница 4: ......

Страница 5: ...nergized connection point Any shock from the tester may result in a hipot test failure Medical Warning Children or individuals wearing a cardiac pacemaker insulin pump or electronically controlled medical device should NOT perform hipot testing For more ideas on improving hipot safety visit the Cirris website at www cirris com testing guidelines hipot_safety html 1 2 Cirris Customer Support For as...

Страница 6: ...Connect USB thumb drive mouse printer head set etc optional 5 Ethernet Connector Connect networking cable optional 6 Audio Port Connect headphones optional 7 Probe Port Connect Probe optional 8 Digital I O Port Allows machines to send signals to and from the test system For more information visit www cirris com and search for digital I O 1 6 Installing Add on Scanners Each add on scanner provides ...

Страница 7: ... 2 Remove the cover plate if you have a 2000 V model there will be two separate cover plates instead of only one In this case remove both cover plates 3 Carefully remove the scanner assembly Put it face down next to the tester ...

Страница 8: ...ch Pro User Manual 4 A plastic cover piece is attached to the right side of the tester by two rivets From the inside of the chassis push both rivets out using a screwdriver or a hard flat object 5 Remove the cover piece ...

Страница 9: ...arefully put the scanner assembly back into the tester Make sure the ribbon connector sticks out from the side of the tester 7 Mate the add on connectors Make sure they are fully connected 8 Push the connectors into the main unit ...

Страница 10: ... tester using the side latches on both sides of the tester If you re attaching more than one scanner add on repeat the procedure attaching the next add on onto the previous one Note If your system is using all seven expansion scanners you will need to purchase a second cable Contact your account manager at Cirris for more information and to purchase this cable 11 Re attach the cover plate ...

Страница 11: ...te Consider where you might place add ons in the future before deciding to use a permanent marker You may want to use removable stickers instead Label the first add on cover plate as follows Label the second add on cover plate as follows etc 1 7 Setting Up the Tester 1 Plug one end of the power cord into the tester Plug the other end into a grounded outlet ...

Страница 12: ...assword is required for the Master Login user To learn how to create user logins and passwords see Setting Up Software Security on page 12 1 8 Using the Touch Screen To navigate the Easy Wire software on your Easy Touch Pro you can touch the screen or use a USB keyboard and mouse plugged into the tester Within this manual the commands touch or press are equivalent to the command click if you ...

Страница 13: ...ester boots up it goes through a series of self tests In the Easy Wire main menu you can tell if the tests pass or fail by checking the status indicator 1 In the Easy Wire main menu verify that the status indicator displays Ready 2 If the status indicator displays Ready the tester is working and ready for use 3 If the status indicator displays Error the tester failed one or more of the self tests ...

Страница 14: ...features are also available for the Easy Touch Pro tester Measured Values The Easy Wire reporting capability allows you to capture and store the measured values of all tests You can store data for low voltage LV and high voltage HV values along with the actual measured values of all components This is called Data Collection when enabled AC High Voltage This option allows you to perform AC hipot te...

Страница 15: ...l number of the tester and the feature being enabled 1 In the Easy Wire main menu press Utilities 2 Press Setup System Options 3 In the Tester Hardware tab press Enable Features 4 The Features Available on this Tester window will display both Features Installed and High Voltage Limits on the left side of the screen Follow instructions 1 3 on the right side of the screen to enable the feature as sh...

Страница 16: ...tration Addendum Easy Wire Software Security This allows you to restrict operator access to the Easy Wire software via user login and password control If each operator on your production floor has a unique user login and password you can track col lected test data down to the individual operator User logins that do not have passwords can be accessed by any of your Easy Touch Pro operators The Easy...

Страница 17: ...ress Create New User from selected user as shown the name will appear as the profile name followed by the word copy 4 Rename the user in the Selected User text box then press anywhere in the white space of the Security Settings box to save the name Note To delete a user right click on the user login and click Delete 5 Select the user name and press Change Password for selected user If you are crea...

Страница 18: ...Adding a Printer below If you have more than one printer you may need to select the desired printer each time you print If the printer you most commonly print to does not display first in the list of printers on the print screen you should change the default printer See Selecting a Default Printer for the Easy Touch Pro User in the I T Administration Addendum on page 7 For further information on n...

Страница 19: ...er icon Select the Cirris user The default Cirris user password is signature1 all lowercase no spaces 6 Install drivers then when prompted plug the printer into the Easy Touch Pro Note If your printer drivers are on a CD you will have to either transfer them to a thumb drive or connect to a network to load the drivers ...

Страница 20: ...16 Cirris Easy Touch Pro User Manual ...

Страница 21: ...gh Voltage adapter part numbers begin with the uppercase letter H e g HHED 26 For more information on which standard adapters are available in high voltage visit www cirris com or call 1 800 441 9910 Custom Adapters These are limited production adapters designed for unique connectors These adapters are identified by a part number starting with a combination of two uppercase letters A followed by 5...

Страница 22: ...position J1 positions J2 J3 and J4 are still available Double high Adapters These adapters support up to 64 test points and consume 64 test points Double high adapters can occupy the J1 and J3 positions The image below shows a Double high adapter in position J1 positions J3 and J4 are still available Quad high Adapters These adapters support up to 120 test points and consume 128 test points Quad h...

Страница 23: ...h the cover plate as was the case with traditional Cirris testers Note The 2000 V model has the traditional cover plates 1 Make sure the slides are pushed completely outward If you have a 2000 V model remove the cover plate 2 Fully insert adapters by pushing the adapter against the edge of the scanner until the adapter fully seats Be careful not to bend the pins Note You must install adapters in t...

Страница 24: ...ers The slides wedge down as you move them inward If you have a 2000 V model reattach the cover plate 2 5 Removing Adapters As with other Cirris scanners adapters in the J3 J4 positions must be removed first 1 Move the slides all the way outward If you have a 2000 V model remove the cover plate ...

Страница 25: ...the missing adapter s Reference your written documentation 2 7 Adapter Signatures Each adapter has a numerical identifier called the Adapter Signature which verifies the test setup Adapter signatures identify how many pins are in the adapter where pin 1 is located and how the pins are numbered Adapter signatures are printed on the adapter labels For more information about Cirris adapters see www c...

Страница 26: ...ese two cables indicate identical connections but different Test Parameter Settings 3F09EF 2J8NH 3F09EF 52AE3 The Cable Signatures for these two cables indicate the same Test Parameter Settings but different connections and connec tors 3F09EF 2J8NH 54GF03 2J8NH Note If a test program has components the parameter signature is MULTI If a test program has advanced hipot settings the parameter signatu...

Страница 27: ...mple cable or import test programs without being prompted to select each adapter in your test program You can create and edit your own adapters and set them as default however the adapters that come with Easy Wire are not editable 1 In the Easy Wire main menu press Connector Type Library 2 Press the User Signature Adapters tab 3 Install the adapter you want to add as a default adapter 4 Press Crea...

Страница 28: ...ished click OK 7 You can come back later and draw a graphical representation of your adapter if desired To move quickly to the next step press No For more information on graphical representations see the Easy Wire help system 8 Select an adapter category and click OK 9 9 If you have more than one attached adapter click Create again and repeat this process substituting the new adapter signature and...

Страница 29: ...w you can set test parameters turn hipot testing on and select components When done press Learn Attached Device Note In this window Use Defaults For Adapters With Shared Signatures is selected by default This allows you to skip the next step if your adapter type is set as a default adapter 7 If you are not prompted to select a part number the tester will learn the sample cable Skip to Verifying Ed...

Страница 30: ...corresponding From and To points Verify that your instruction list is correct for the learned cable If necessary you can add delete and edit instructions or change instruction types Note You can open the Set Test Defaults tab tab 2 to change your test methods parameters and set up test reports The View Nets tab tab 4 displays the instruction list in a net list format The Label Points tab tab 5 all...

Страница 31: ... will display Ready to Test Press Start 3 If the low voltage test fails the information bar will display Bad and the error s will be displayed in the test window along with the error signature If the low voltage test passes and no hipot is set the information bar will display Good If hipot is set to automatic mode the information bar will display Hipotting If hipot is set to manual the information...

Страница 32: ... manual may be printed if desired 1 Press Help in any window in Easy Wire The help information for that window will open 2 If there is an information bar at the top of the screen right click the information bar and then press Allow Blocked Content If there is no information bar skip to step 4 3 When the security warning opens press Yes 4 To view the entire Easy Wire manual by chapter press Content...

Страница 33: ...sible externally In order to share the two Cirris has made it possible to make a bridge To form this bridge you must first create a special Easy Wire category that points to the directory path where the T1 1100 wir files are located Next you must import the T1 1100 test programs into the Easy Wire database and assign them to the catego ry Then you can edit a test program in either location and the...

Страница 34: ...ch Pro tester either on a thumb drive locally or on a network 2 In the Easy Wire main menu press Utilities 3 Press Category Maintenance 4 In the first text drop down box select New Category Note The pre defined categories Demo Military and Standard cannot see a file location outside of Easy Wire You must create a new category ...

Страница 35: ...he category for specific customers 6 Ensure that the Test Program box is selected 7 Press the Master File Directory browse button 8 Browse to the file location that contains your Touch 1 or 1100 wirelists In this example the Touch 1 files are in drive D in a folder called Touch 1 Select the folder and press OK ...

Страница 36: ...or 1100 wirelists into the Easy Touch Pro database Important During the importing process you will have the option to select a category for imported test program s Ensure that you select the category you created in step 4 This will allow wirelists to be synchronized in both the Easy Touch Pro database and your Touch 1 or 1100 file location 12 See Importing Touch 1 or 1100 Wirelists on the next pag...

Страница 37: ...If your testers are networked proceed to step 2 below If your testers are not networked you will need to copy your files to a thumb drive and then plug your thumb drive into your Easy Touch Pro tester If you have a Touch 1 use a floppy drive and a PC to transfer the files If you have an 1100 with USB ports you can copy the files directly to the thumb drive If you have an 1100 with no USB ports tra...

Страница 38: ...e part number for the first adapter position in the test and press OK Note If you have multiple adapters you will be prompted to repeat this step for each adapter in the test 7 If you have more wirelists to import press Import WIR Files and repeat steps 1 6 or multi select the wirelists 8 When you have imported all of your wirelists press Done 9 Press Done to return to the main menu ...

Страница 39: ...m between the Easy Wire database and the Touch 1 or 1100 file location Note In the Easy Wire main menu you can assign existing test programs to the category for shared wirelists if you want to use them on your Touch 1 or 1100 tester See Moving Test Programs Between Categories in the next section 3 9 Moving Test Programs between Categories In the Easy Wire main menu you can move any test program to...

Страница 40: ...36 Cirris Easy Touch Pro User Manual ...

Страница 41: ... modular in design for easy servicing If your Cirris tester requires service as determined by Cirris support personnel you may need to send the affected module or the entire tester back to Cirris for repair A loaner tester can be sent to you You should not attempt to service any circuit board at the component level All component level service should be performed by Cirris technicians 4 4 Calibrati...

Страница 42: ...utputs without the use of a PLC Easy Wire software version 2012 2 or higher has Digital I O capability See the Easy Wire help system for more information 4 6 Conditions for Operation Your Easy Touch Pro Tester is intended to be used indoors at a temperature of 50 to 104 degrees Fahrenheit 10 to 40 de grees Celsius Best performance can be obtained at a relative humidity of less than 70 Insulation R...

Страница 43: ...Systems Corporation is not responsible for special incidental or consequential damages resulting from any breach of warranty or under any other legal theory including lost profits downtime goodwill damage to or replacement of equipment and property and any costs of recovering materials used with the Easy Touch Pro Analyzer ANY IMPLIED WARRANTIES ARISING OUT OF SALES OF THE Easy Touch ANALYZER INCL...

Страница 44: ...40 Cirris Easy Touch Pro User Manual ...

Страница 45: ... 41 ...

Страница 46: ...Easy Touch Pro Getting Started Guide Version 2017 1 0 2016 Cirris Systems Corporation 401 North 5600 West Salt Lake City UT 84116 USA www cirris com ...