Страница 1: ...INSTRUCTION MANUAL M259B01 03 20B Energy manager line EDS PS line EDS PSS line EDS PSS PRO ...

Страница 2: ...2 line EDS PSxxx Instruction Manual ...

Страница 3: ...ollowing should be taken into consideration Incorrect handling or installation of the unit may result in injury to personnel as well as damage to the unit In particular handling with voltages applied may result in electric shock which may cause death or serious injury to personnel Defective installation or maintenance may also lead to the risk of fire Read the manual carefully prior to connecting ...

Страница 4: ...NSTALLATION 11 3 6 CONNECTION DIAGRAM 13 4 OPERATION 14 4 1 OPERATING PRINCIPLE 14 4 2 LED INDICATORS 14 4 3 DIGITAL OUTPUTS 16 5 COMMUNICATIONS 17 5 1 RS 485 COMMUNICATIONS 17 5 1 1 CONNECTIONS 17 5 2 Wi Fi COMMUNICATIONS 18 5 2 1 USAGE ENVIRONMENT AND HEALTH 18 5 2 2 Wi Fi COMMUNICATIONS 18 6 CONFIGURATION WEBSITE 19 6 1 NETWORK SETUP 20 6 2 TIME SETUP 21 6 3 ACTIVE MODE 21 6 4 SECURITY SETUP 22...

Страница 5: ...or illustrative use only and may differ from the original device SYMBOLS Table 2 Symbols Symbol Description In accordance with the relevant European directive In accordance with the CMiM directive Device covered by European Directive 2012 19 EC At the end of its useful life do not leave the device in a household refuse bin Follow local regulations on electronic equipment recycling Direct current A...

Страница 6: ...RCUTOR s after sales service 2 PRODUCT DESCRIPTION line EDS PSxxx is a device that works as connector between field devices with Modbus RTU or Mod bus TCP communications and the PowerStudio energy management software Circutor has 3 models line EDS PS with embedded PowerStudio line EDS PSS with embedded PowerStudio SCADA line EDS PSS PRO with embedded PowerStudio SCADA DELUXE The device features 5 ...

Страница 7: ... to heed the warnings and or recommendations set out in this manual nor for damage resulting from the use of non original products or accessories or those made by other manufacturers Do not use the device to perform any operation if you detect any anomaly or malfunction Before carrying out maintenance repair or handling of any of the device s connections the device must be disconnected from all po...

Страница 8: ...rates how the panel adapter connects to a line EDS PSxxx Before installing the adapter the device must be disconnected from all power and measurement supplies Figure 1 Installation of the panel adapter Table 3 Technical characteristics of the Panel Adapter Technical Specifications Protection degree IP40 Casing Self extinguishing V0 plastic 68 mm 68 mm Figure 2 Cut in the panel 8 line EDS PSxxx Ins...

Страница 9: ...PSxxx devices can be expanded with other devices in the line range the line CVM and line M expansion modules The line EDS PSxxx and line CVM devices enable up to 2 expansion modules to be directly connected to their right hand side 1 line EDS line M line M line M line M line CVM Figure 4 line EDS PSxxx and line CVM expansion module connection 1 Expansion module types line M 4IO R line M 4IO T line...

Страница 10: ...nd side of the devices to be fed It can supply up to 10 VA allowing it to power a limited number of devices The maximum set it can supply is 1 line EDS PSxxx 1 line CVM 1 line M Figure 6 line EDS line M line M EXT PS line CVM Figure 6 Maximum set a line M EXT PS can supply Multiple line M EXT PS devices can be connected to supply sets with power above 10VA Each line M EXT PS will power the devices...

Страница 11: ...rewdriver remove the expansion connector s protective covers located on the side of the devices Figure 8 Figure 8 Installation step 1 2 Insert the expansion connector and fastening clips into one of the devices Figure 9 Figure 9 Installation step 2 3 Connect both devices and fasten them by pushing the front clips down Figure 10 11 Instruction Manual line EDS PSxxx ...

Страница 12: ...nstallation of all devices please refer to the instruction manual for the different models M237B01 01 xxx Instruction Manual for line CVM devices M239B01 03 xxx Instruction Manual for line M expansion modules 12 line EDS PSxxx Instruction Manual ...

Страница 13: ...ER With a browser compatible with HTML5 With a browser compatible with HTML5 Con navegador Web compatible con HTML5 Con navegador Web compatible con HTML5 LAN WLAN SLAVES line EDS A B S Figure 11 line EDS PS line EDS PSS and line EDS PSS PRO connection diagram 13 Instruction Manual line EDS PSxxx ...

Страница 14: ...ata to the PowerStudio energy management software Three device models are available depending on the management software line EDS PS for the embedded PowerStudio software line EDS PSS for the PowerStudio SCADA software line EDS PSS PRO pfor the PowerStudio SCADA DELUXE software 4 2 LED INDICATORS The devices have 5 indicating LEDs LAN WLAN SLAVES line EDS WLAN LAN CPU SLAVES ALARMA ALARM Figure 12...

Страница 15: ...on Table 7 WLAN LED LED Description WLAN On blue color Connection to a Wi Fi network Flashing blue color Activity in the Wi Fi network ALARM Table 8 ALARM LED LED Description CPU On red color Alarm activated SLAVES Connection with slave device Table 9 SLAVES LED LED Description SLAVES On red color The slave device doesn t communicate 15 Instruction Manual line EDS PSxxx ...

Страница 16: ...puts optoisolator NPN transistors terminals 19 20 and 21 in Figure 3 19 Carga Load Fuente externa External load Salidas de transistor Transistor outputs 21 1 2 C LAN WLAN SLAVES line EDS Figure 13 Digital outputs 16 line EDS PSxxx Instruction Manual ...

Страница 17: ...with mesh shield minimum 3 wires with a maximum distance of 1200 meters between the line EDS PSxxx and the slave devices In this bus we can connect a maximum of 32 slave devices RS 485 A B S A B S LAN WLAN SLAVES line EDS A B S A B S A B S A B S line EDS CVM E3 MINI CVM E3 MINI Ethernet SERVIDOR SERVER Figure 14 RS 485 connection diagram 17 Instruction Manual line EDS PSxxx ...

Страница 18: ...l devices implanted in the human body pacemak ers etc In any other setting where the risk of interference with other devices or services is a hazard If you are not sure of the applicable usage policy for wireless devices in a specific organisation airport hospital etc we recommend requesting permission to use wireless communications 5 2 2 Wi Fi COMMUNICATIONS Wi Fi is one of the most widely used w...

Страница 19: ...rver of the local area network LAN Note The device leaves the factory with DHCP activated Note To find the device in a local network a crossover cable has to be used to access the device s local IP 100 0 0 1 with a subnet mask 255 255 255 0 If a username and login password have been set up when trying to access via the web the website requests these login parameters on the following pop up screen ...

Страница 20: ... Identifying name within the local network DHCP If DHCP is enabled DHCP On the IP address is dynamically assigned by a central server and no further parameters need to be configured If this option is disabled the IP address is fixed and the following parameters need to be configured DHCP Client ID Device ID Address IP address Netmask IP subnet mask Gateway Gateway 20 line EDS PSxxx Instruction Man...

Страница 21: ...inverts the role of the process for connecting remote devices The devices are the ones that initiate the communication process with the connection server located on a central computer creating a transparent communication tunnel between the device and server This avoids the requirement of having a fixed IP or DynDNS system at the user s remote control sites Figure 19 Configuration website Active mo...

Страница 22: ...e New password login password Repeat password repeat the login password 6 5 INFORMATION This section shows the information on the line EDS PSxxx device Figure 21 Configuration website Information MAC MAC address Version Upgrade Firmware version of the device Powerstudio version PowerStudio software version Device status Status of the device Press to save the device configuration Press to load the ...

Страница 23: ...9600 19200 38400 57600 115200 bps Data bits 8 Stop bits 1 2 Parity without Ethernet communication Type Ethernet 10BaseT 100BaseTX self detectable Connector RJ45 Protocol Web server XML Connection mode to Network DHCP ON OFF ON by default Secondary service IP address 100 0 0 1 Wi Fi communication Band 2 4 GHz Standard IEEE 802 11 ac a b g n Output power 8 9 dBm Effective radiated power ERP 11 25 dB...

Страница 24: ... use Part 1 General requirements EN 61010 1 Electromagnetic compatibility EMC Part 6 2 Generic standards Immunity for industrial environments EN 61000 6 2 Electromagnetic compatibility EMC Part 6 4 Generic standards Emission standard for industrial environments EN 61000 6 4 Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use Part 1 General Requirements UL 61010 ...

Страница 25: ...mproper installation or improper usage of the unit Consequently this guarantee does not apply to failures occurring in the following cases Overvoltages and or electrical disturbances in the supply Water if the product does not have the appropriate IP classification Poor ventilation and or excessive temperatures Improper installation and or lack of maintenance Buyer repairs or modifications without...

Страница 26: ...10 CE CERTIFICATE 26 line EDS PSxxx Instruction Manual ...

Страница 27: ...27 Instruction Manual line EDS PSxxx ...

Страница 28: ...28 line EDS PSxxx Instruction Manual ...

Страница 29: ...29 Instruction Manual line EDS PSxxx ...

Страница 30: ...CIRCUTOR SA Vial Sant Jordi s n 08232 Viladecavalls Barcelona Tel 34 93 745 29 00 Fax 34 93 745 29 14 www circutor es central circutor com ...