background image

eHome Link

INSTRUCTION MANUAL

(M354B01-03-22A)

Содержание eHome Link

Страница 1: ...eHome Link INSTRUCTION MANUAL M354B01 03 22A...

Страница 2: ...eHome Link 2 Instruction Manual...

Страница 3: ...sclaimer CIRCUTOR SA reserves the right to make modifications to the device or the unit specifications set out in this instruction manual without prior notice CIRCUTOR SA on its web site supplies its...

Страница 4: ...part of this manual can be reproduced copied translated or transmitted in any form or by any means without the prior written permission of the original manufacturer Information provided in this manual...

Страница 5: ...ur manual to use eHome Link Disclaimer 3 Revision log 3 Here s your manual to use eHome Link 5 1 So hello 6 2 Overview 8 3 Operating Instructions 10 A Charging procedure 11 B Error states 13 4 Additio...

Страница 6: ...TION IN THIS DOCUMENT ELECTRIC RISK Take precautions to make the electrical connection inside the unit Unit must be disconnected from any power source during commissioning ATTENTION Indicates that the...

Страница 7: ...r purpose than electric vehicle charging modes as specified in IEC 61851 Do not modify this unit If modified CIRCUTOR will reject all responsibility and the warranty will be void The Charge point does...

Страница 8: ...cially designed to be easily installed in private car parks both indoors and out for the purpose of charging every EV model on the market in MODE 3 in accordance with the European IEC 61851 1 standard...

Страница 9: ...eHome Link 9 Instruction Manual 1 Plugs may vary depending on the model Overview 1 2 6 3 5 4 1 CIRCUTOR Logo 2 Status LED bar 3 Front cover 4 Cable Connector 5 Frame 6 Socket outlet 1...

Страница 10: ...eHome Link 10 Instruction Manual 3...

Страница 11: ...ans that the unit is available and ready to start the charge 2 PLUG To start a new charge process plug the connector into your car and in the Charge Point 3 BLUE FIX LED STATUS When the status LED lig...

Страница 12: ...harge process is completed the status LED light bar stops flashing and remains fixed in blue 6 UNPLUG At this moment you can unplug the vehicle connector from the car and from the Charge Point if it i...

Страница 13: ...1 Blink Sequence Error states The eHome Link is capable of detecting the following operating errors Disabled Socket outlet D state Error E state Error Proximity Error Negative PWM voltage Error RCD Er...

Страница 14: ...and flashes in a sequence of three blinks 3 Blink Sequence 5 NEGATIVE PWM VOLTAGE ERROR When the Charge Point is connected to the EV the PWM signal used to communicate the Charge Point with the EV ca...

Страница 15: ...An internal short circuit has been detected In this case the status led light bar turns red and flashes in a sequence of seven blinks 9 TEMPERATURE ERROR When the Charge Point temperature is above a c...

Страница 16: ...it will reconnect automatically once the voltage safe value of 247 V is reached RCD DC 6 mA LEAK AGE DETECTOR This protective function detects leakage current in order to prevent any electric hazards...

Страница 17: ...vices has been improperly used or the storage installation and maintenance instructions listed in this manual have not been followed Improper usage is defined as any operating or storage condition con...