Using the reset command @SR, the MU4-RS2 can be reset to the status when the power was turned on.   
The parameters set in the EEPROM remain unchanged. 
 
 
 

 

Reset  the  unit  to  the  factory  default  settings  if  communication  with  the  MU-4  mounted  on  the  MU4-RS2  is  not 
possible or if you are uncertain of the internal settings. 
 

How to initialize the MU-4 

Turn on the power while pressing the initialize button. Then turn the power off and on once again to reset the unit to 
the  default  settings.  For  details  of  the  default  status,  refer  to  the  default  values  for  each  command  in  the  MU-4 
Operation guide. 
The MU-4 can also be initialized using the initialize command @IZ.

 

 

Status after initializing 

The values of the main parameters after initializing are as follows.

 

1. Link related parameters

 

User ID: UI = 0000, Group ID: GI = 00, Equipment ID: EI = 01, Destination ID: DI = 01, Channel = 0 channel

 

2. UART related parameters

 

Baud rate = 19,200 bps, parity = none, stop bit = 1

 

3. Parameters related to internal operation

 

Mode = command 

 
 

 
The  diagram  below  is  an  example  of  how  to  connect  the  MU4-RS2  and  the  single-chip  CPU.  Insert  an  RS232C 
transceiver in the CPU signal line. 
Since the MU4-RS2 DTR line is connected to the MU-4 MODE terminal, be sure to control the level in accordance 
with the MU-4 mode being used. 
 
 
 

2

1

VCC

GND

MU-4

λ

/4

Lead antenna

Regulator

+3v

2

3

4

5

6

7

1

8

10

11

12

9

13

14

INI

RXD

TXD

RTS
CTS

MODE

RESET

DI

RF

GND
VCC
AF-MON
DO
TX-LED
RX-LED

+

-

LED1

LED2

LED3

CN1

Power terminal

DC

 

+3.2v

+12v

SW1

Power switch

 

1

RXD

2

TXD

3

DTR

4

GND

5

DSR

6

RTS

7

CTS

8
9

CN2

D-Sub 9pin

male

SW2

initialize

1
2

RXD

3

TXD

4

DTR

5

GND

6

DSR

7

RTS

8

CTS

9

RS232C

level conversion

RS232C

level conversion

CPU

RXD
TXD

RTS

CTS

Output Port

(Mode control)

Straight cable

User system

MU4-RS2(RS232C interface board + MU-4)

 

 

3.3 Initializing 

3.2 Resetting 

3.4 Connection example 

Содержание MU-4 RS232C

Страница 1: ...power radio modem MU 4 MU 4 RS232C Interface Board MU4 RS2IF Operation Guide Version 1 0 Sep 2020 CIRCUIT DESIGN INC 7557 1 Hotaka Azumino city Nagano 399 8303 JAPAN Tel 81 0263 82 1024 Fax 81 0263 82...

Страница 2: ...unctions 5 2 2 Block Diagram 6 2 3 Main Specifications 7 2 4 Channel Table 7 2 5 External dimensions 8 2 6 Circuit Diagram 9 Chapter 3 How to Use the MU4 RS2 10 3 1 System Configuration Example 10 3 2...

Страница 3: ...venience the MU 4 RS232C interface board MU4 RS2IF with the embedded low power radio modem MU 4 mounted on it is referred to as the MU4 RS2 Before using the board mount the MU 4 on the MU4 RS2IF When...

Страница 4: ...user systems are publicly available Compact size 47 71 18 mm fits in a small housing Features of the MU2 ESP evaluation program 1 You can issue all commands for controlling the interface board with m...

Страница 5: ...ents are as follows First please check that you have all the items 1 4 1 Accessories 1 MU 4 RS232C interface board MU4 RS2IF 1 2 Battery holder 1 3 Spacers used as legs 10 mm 4 4 Screws for spacers M...

Страница 6: ...n off the power and on once again after a while approx 5 seconds 07 Power LED The LED comes on when the power switch is turned on 08 Power switch A power switch Check that the power terminal is connec...

Страница 7: ...2 4 5 6 7 1 8 9 12 11 10 13 14 INI RXD TXD RTS CTS MOD RST RXM RF GND VCC DI DO RXL CN1 DC 3 2v 12v LED1 LED3 LED2 Power terminal SW1 Power switch 1 RXD 2 TXD 3 DTR 4 GND 5 DSR 6 RTS 7 CTS 8 9 CN2 D...

Страница 8: ...nnector D Sub 9 pin male Refer to the operation guide of the MU 4 mounted on the MU4 RS2IF for the channel table The frequency band is shown on the label of the MU 4 Parameter Specification Unit Remar...

Страница 9: ...cuit Design Inc 8 OPERATION GUIDE MU4 RS2 MU 4 MU4 RS2IF 2 5 External Dimensions 30 8 25 7 9 14 2 6 6 5 17 4 47 40 64 57 51 1 6 7 1 4 lead antenna 180 4 3 RF GND VCC RXD CTS INI RXM DO RXL TXD RTS MOD...

Страница 10: ...OG_MU4 RS2IF_v10e Circuit Design Inc 9 OPERATION GUIDE 2 6 Circuit Diagram MU 4...

Страница 11: ...55 GI 02 EI 03 UI 0055 GI 02 EI 04 MU2 RS2 MU4 RS2 Group2 1 N system Group3 1 N system Note UI User ID GI Group ID EI Equipment ID DI Destination ID Since it is treated in the same way as the MU 4 ref...

Страница 12: ...UI 0000 Group ID GI 00 Equipment ID EI 01 Destination ID DI 01 Channel 0 channel 2 UART related parameters Baud rate 19 200 bps parity none stop bit 1 3 Parameters related to internal operation Mode...

Страница 13: ...l LED terminals have been newly added to this product In addition if you attach LEDs to the case connect them with inch pitch through holes with reference to the diagram below MU 4 RS232C cable User P...

Страница 14: ...tion of a ground in order to exploit its performance fully connect it to the largest possible ground pattern when mounting the MU 4 on your circuit board In addition in the case of two way communicati...

Страница 15: ...e MU4 RS2 MU 4 MU4 RS2IF is a program that accesses the COM port The method of developing a program is basically the same as for the MU 4 except for accessing a virtual COM port Refer to Chapter 6 How...

Страница 16: ...cuits and reverse connections may result in overheating and damage and must be avoided at all costs Ensure that the power supply has been switched off before attempting any wiring work The case is con...

Страница 17: ...OG_MU4 RS2IF_v10e Circuit Design Inc 16 OPERATION GUIDE REVISION HISTORY Version Date Description Remark 1 0 Sep 2020 MU4 RS2IF The first issue...

Отзывы: