OG_MU-4-434_v10e Circuit Design, Inc.
56
OPERATION GUIDE
5.4.5.3 ‘@DT05@CTxx/C’ Issue target station test data
Issues link test data from the specified target station for the time specified with the count value.
The transmission data is the ‘
C
R
L
F
’ sent repeatedly, and the receive response of the receiving station is ‘*DR=00’. If
there is any input data during transmission, the data is transmitted. Note that once continuous data is issued from
the target station, it cannot be stopped by radio.
Format 1: ‘@’ + ‘DT05’ + ‘@CT’ + count value + ‘/C’ + route infor ‘C
R
L
F
’
Format 2: ‘@’ + ‘DT05’ + ‘@CT’ + count value + ‘/C’ + ‘C
R
L
F
’
Details
Format 1: ‘@DT05’ ‘@CT’ xx ‘/C’ rr,rr,...,rr ‘
C
R
L
F
’
Format 2: ‘@DT05’ ‘@CT’ xx ‘/C’ ‘
C
R
L
F
’
xx:
Count value: ASCII code that expresses 01h to FFh
The count value is 10 seconds per count. The maximum value is FFh, 2,550 seconds.
rr,rr,...,rr:
Shows the route information in 2 hexadecimal digits and ASCII characters. Value: 00h to FEh,
number of relay stations maximum 10 units
The count value is 10 seconds per count. The maximum value is FFh, 2,550 seconds.
With Format 1, the route information is entered directly in the command.
With Format 2, transmission is based on route information set in the route register with the RT command or in
the content of the Destination ID. When entering the route information, enter the Equipment ID of the target unit
at the end. If no route information is set (NA set for the RT command), the equipment set as the Destination ID
will be the target station.
Example: Issue a test signal for 60 seconds from the target station equipment number = 8F. The relay stations are
01 and 02.
・Source station 5F status
①Issue the extended command
Format 1:@DT 05 @CT 06 /C 01,02,8F C
R
L
F
Format 2:@DT 05 @CT 06 /C C
R
L
F
②Extended response *DT=05 C
R
L
F
・Target station 8F status
⑥ACK return (Test data issue completion notice)
②
⑦
User
controller
User
controller
Target
station
EI=8F
Relay
station
EI=02
Relay
station
EI=01
Source
station
EI=5F
①
③Request to
issue test data
⑥ACK return
⑤Issue test data for 60 seconds
③Request to issue test data
⑤
Issue test data
※The test data issued from the target station
is not relayed
⑦ACK response
(issued after the relay time has elapsed)
*DR=05 @CT06 C
R
L
F
④
④There is no data receive
ACK response (Source station output)
When test data is issued from the target station, the issue completion result is output as an ACK response.
• Source station ACK response output
*DR = 05 @CT06
C
R
L
F