SERVICE MANUAL
–
Post eVolve Smart
14 - TECHNICAL DATA
CIRCONTROL, S.A.
–
Innovació, 3
–
08232
–
Viladecavalls (Barcelona)
Tel.: +34 937 362 940
–
Fax: +34 937 362 941
97
Web: www.circontrol.com
–
E-mail:
14.9
MODEL TM4
INPUT
Input voltage
400VAC Three-phase
Nominal input current
64A
Nominal input power
44kW
Input frequency
50/60Hz
OUTPUTS
PLUG A
PLUG B
TYPE 2
CEE 7/3
TYPE 2
CEE 7/3
Rated output current
32A
16A
32A
16A
Rated output
22kW
3,6kW
22kW
3,6kW
Output AC voltage
400VAC
Three-
phase
230VAC
Single-
phase
400VAC
Three-
phase
230VAC
Single-
phase
CHARGE SYSTEM
PLUG A
PLUG B
TYPE 2
Mode 3 (IEC 61851)
Mode 3 (IEC 61851)
CEE 7/3
Mode 1 (IEC 61851)
Mode 1 (IEC 61851)
PROTECTIONS
PLUG A
PLUG B
OUTPUT TYPE 2
MCB
Type A
40A
40A
RCD
Curve C
30mA
30mA
OUTPUT CEE 7/3
MCB
Type A
16A
16A
SOCKET OUTLETS
2 x Type 2 + 2 x CEE 7/3