3.3.
Symptom: No resistance when pedaling.
Check LED on EMS controller
Flashing (3 times
per second)
UART ERR (Communication
abnormal). Please restart to
re-establish communication. If the
led light is flashing (3 times per
second), it’s abnormal. (Check if
the console PCB, Motor PCB or
connection wires are normally.)
Flashing (once
per second)
Machine is running
normally.
(Normal Status)
Stays on
Machine is standby.
(Normal Status)