background image

techno

logical

 solutions

TECHNICAL DATA SHEET

Cav. Uff. Giacomo Cimberio S.p.A.

FIXED ORIFICE
BALANCING VALVE

747

Main features:

Cim 747 is used for balancing the flow in cooling, heating and domestic water systems.
Cim 747 is a combined manual presetting valve with following features:
•  Fixed measurement orifice;
•  Supplied with 2 pcs. of measuring nipples for needles;
•  Handwheel with shut-off function and clear 360° reading;
•  Digital scale with lock function;
•  Measuring accuracy of fixed orifice ± 5%.

It is supplied with internal thread.
It is made of standard brass, “CR” brass (“CR” - Corrosion Resistant) and “NL” brass (“NL” - 
No lead).

This article is made in compliance with the quality management requirements of ISO 
9001:2008 standard.
All articles are tested according to the EN 12266-1:2003 standard.
It can be used in a wide variety of sectors: heating, air conditioning, water, sanitary systems 
and generally with any non corrosive liquid.

PN 25

Approved by*:

Technical data:

Max. static working pressure 

 

 

25 bar

Max. flow temperature   

 

 

120 °C - 150°C (Cim 747OTS)

Min. 

temperature    -10°C

Fluids: 

     Water 

and 

Glycol

Material of parts in contact with water:
      Valve 

body;

      Spindle;
      Cone, 

etc. 

Materials:
      “CR”Brass 

(EN 

1982-CC752S) 

      Standard 

Brass 

(EN 

1982-CC754S)

      “NL” 

Brass 

(EN 

1982-CC752S 

low 

lead) 

O-rings: 

     EPDM 

Perox

Threads:     ISO 

7

1

*Cim 747

Rev

. 1 del 11/2013

Содержание CIM 747

Страница 1: ...ss CR brass CR Corrosion Resistant and NL brass NL No lead This article is made in compliance with the quality management requirements of ISO 9001 2008 standard All articles are tested according to th...

Страница 2: ...ass DN Material Thread Kv Kvs Technical Code 15 NL Brass EN 1982 CC752S low lead 1 2 Rp 0 515 1 75 1 80 DA03491015 20 3 4 Rp 0 842 3 77 4 10 DA03491020 25 1 Rp 0 943 6 96 7 50 DA03491025 32 1 1 4 Rp 1...

Страница 3: ...Technical Code 15 CR Brass EN 1982 CC752S 15x15 0 515 1 75 1 80 DA02935015 20 18x18 0 842 3 77 4 10 DA02935018 20 22x22 0 842 3 77 4 10 DA02935022 25 28x28 0 943 6 96 7 50 DA02935028 32 35x35 1 316 1...

Страница 4: ...13 Knob 14 Pin 15 Index 16 Entrainer 17 O ring 18 Memory 19 Cup 20 Blue binder point 21 Red binder point Installation procedure Before installation of Cim 747 check that inside the valve and the pipes...

Страница 5: ...opening of the obturator while the second circular one from 0 up to 9 registers the tenths of one turn The position of the handle for the required flow rate can be memorized by an Allen Key 6 mm Sizi...

Страница 6: ...rable As a general rule it is better to choose the valve with the smallest diameter in this way the valve will be quite opened and there will be no problem with noises and cavitations Measuring the pr...

Страница 7: ...re centimetre atm atmosphere 10 3323 mH2O metres of water atm atmosphere 14 6959 psi pound per square inch Kg cm2 10 mH2O metres of water Kg cm2 14 2233 psi pound per square inch mH2O 1 42233 psi poun...

Страница 8: ...p kPa 1 10 100 Flow rate Q l s Turns N 7 8 6 5 4 3 2 Kv Flow rate in m3 h 1 bar pressure drop Full turn Tenths of turn 0 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 2 0 515 0 549 0 583 0 617 0 650 0 684 0...

Страница 9: ...te Q l s 0 2 0 4 0 6 0 8 1 Turns N 7 8 6 5 4 3 2 Kv Flow rate in m3 h 1 bar pressure drop Full turn Tenths of turn 0 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 2 0 842 0 918 0 993 1 069 1 144 1 220 1 295 1...

Страница 10: ...ate Q l s 0 2 0 4 0 6 0 8 1 Turns N 8 7 6 5 4 3 2 Kv Flow rate in m3 h 1 bar pressure drop Full turn Tenths of turn 0 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 2 0 943 1 052 1 162 1 271 1 380 1 490 1 599...

Страница 11: ...l s 2 3 4 6 Turns N 8 7 6 5 4 3 2 Kv Flow rate in m3 h 1 bar pressure drop Full turn Tenths of turn 0 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 2 1 316 1 486 1 655 1 825 1 995 2 165 2 334 2 504 2 674 2 84...

Страница 12: ...8 10 Turns N 8 7 6 5 4 3 2 Kv Flow rate in m3 h 1 bar pressure drop Full turn Tenths of turn 0 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 2 2 220 2 473 2 726 2 979 3 232 3 485 3 738 3 991 4 244 4 497 3 4 7...

Страница 13: ...urns N 8 7 6 5 4 3 2 Kv Flow rate in m3 h 1 bar pressure drop Full turn Tenths of turn 0 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 2 2 510 3 143 3 776 4 409 5 042 5 675 6 308 6 941 7 574 8 207 3 8 840 9 6...

Страница 14: ...0 8 1 Turns N 8 7 6 5 4 3 2 2 5 O P E N Kv Flow rate in m3 h 1 bar pressure drop Full turn Tenths of turn 0 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 2 0 67 0 71 0 75 0 78 0 82 0 86 0 90 0 95 0 99 1 03 3...

Страница 15: ...0 8 1 Turns N 8 7 6 5 4 3 2 2 5 O P E N Kv Flow rate in m3 h 1 bar pressure drop Full turn Tenths of turn 0 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 2 1 00 1 09 1 16 1 24 1 31 1 41 1 50 1 60 1 69 1 78 3...

Страница 16: ...8 7 6 5 4 3 2 36 P V K Q Kv Flow rate in m3 h 1 bar pressure drop Full turn Tenths of turn 0 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 2 0 95 1 02 1 10 1 20 1 31 1 40 1 50 1 62 1 74 1 87 3 2 00 2 11 2 26...

Страница 17: ...3 2 36 P V K Q Kv Flow rate in m3 h 1 bar pressure drop Full turn Tenths of turn 0 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 2 1 16 1 28 1 42 1 57 1 73 1 88 2 07 2 24 2 45 2 69 3 2 91 3 15 3 42 3 68 3 95...

Страница 18: ...6 5 4 3 2 Kvs Flow rate in m3 h 1 bar pressure drop Full turn Tenths of turn 0 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 2 2 27 2 44 2 62 2 81 3 04 3 27 3 52 3 76 4 11 4 43 3 4 78 5 12 5 49 5 91 6 29 6 7...

Страница 19: ...V K Q Kv Flow rate in m3 h 1 bar pressure drop Full turn Tenths of turn 0 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 2 1 82 2 29 2 87 3 42 4 04 4 61 5 28 5 90 6 61 7 29 3 8 01 8 86 9 59 10 45 11 21 12 09 1...

Страница 20: ...980 1140 1660 2500 3740 A 51 51 51 51 57 57 B 111 128 138 141 5 181 190 5 C 85 97 113 144 163 193 C1 163 187 188 208 5 260 281 5 D 16 5 18 21 23 23 28 E 184 215 223 244 308 337 CH 28 33 40 51 56 71 DN...

Страница 21: ...y 1 Lift the index scale 6 placed over the bonnet 4 remove the pins 7 using the suitable tool unthread the handle 8 and the reference ring 5 Unscrew the bonnet 4 with a key acting on the hexagonal sid...

Страница 22: ...923001 Fax 39 0322 967216 967755 s k y p e c i m b e r i o s k 1 c i m b e r i o s k 2 info cimberio it www cimberio com Copyright Cav Uff GIACOMO CIMBERIO S p A All rights reserved Tutti i diritti r...

Отзывы: