PELLET’S BOILER FUTURA PICUS

 

 

 

 

 

Designed and tested in Sweden ! 

 

 

 
 
 
 
 
 
 
 
 
 
 

Содержание Futura 35

Страница 1: ...www cichewicz com YOUR HEATING OUR RESPONSIBILITY 1 PELLET S BOILER FUTURA PICUS Designed and tested in Sweden...

Страница 2: ...rtment houses etc We can provide also bigger units f e up to 200 kW but all dimensions and features of the system are individually proposed to the customer Boiler was tested on different burners from...

Страница 3: ...rms in Europe Tab 1 Dimensions and technical parameters of boiler Parameter SI FUTURA 25 FUTURA 35 FUTURA 60 Weight kg 350 480 580 Water capacity l 60 100 130 Fuel hopper capacity l 160 160 250 Dimens...

Страница 4: ...whole construction is located on the wheel It provides easy transport and easy arrangement of the boiler room In the lower part of the fuel hopper feeding screw mechanism is located Motor and steerin...

Страница 5: ...hewicz com YOUR HEATING OUR RESPONSIBILITY 5 3 2 Burner s description Door contact breaker Fan Igniter connection Photo resistor Control cable Backside fire protection Feed tube Gable Ground cable con...

Страница 6: ...closed overheat thermostats for furnace and feed tube and also furnace door security switch Lamp indicating feed screw movements Lamp indicating connected igniter Strapping in fuse box Connection of o...

Страница 7: ...n and operation of the boiler it is very important to keep safe distance from the inflammable materials The boiler is allowed to work only in open type heating systems b Electrical installation the bo...

Страница 8: ...inflammability class is known the distance should be doubled Tab 9 Inflammability classes for building materials Inflammability classes for building materials Materials A non flammable sandstone conc...

Страница 9: ...ause big variations in chimney draught This affects the conditions for a high efficiency in the burner and the settings that have been made A draught stabiliser mounted after the furnace helps level t...

Страница 10: ...e are made of lacquered steel plate The burner housing serves as a hold for the combustion part and the detachable gable Also the igniter is attached inside the gable The burner housing gable serves a...

Страница 11: ...e thermostat overheating protection and operating thermostat can be used to control the burner The start temperature on the burner is set on the furnace s operating thermostat Note that the thermostat...

Страница 12: ...connected both via the overheating protection and the furnace s operating thermostat and since the burner is equipped with a separate temperature control the furnace s operating thermostat must be put...

Страница 13: ...h the burner will work see Manual for Control Unit Starting Dose Loosen the hose from the burner and hold a litre measure below it Start the burner and wait until the feed screw has fed the starting d...

Страница 14: ...temperature sensor make sure that any extern start signal is in off position Simultaneously press A B OK TEST position indicates by flashing in the furthest down to the right in the display The test...

Страница 15: ...ed The boiler room should be kept clean and dry Any manipulations in mechanical or electrical parts of the boiler are forbidden Manual for Control Unit Description The control unit consists of a contr...

Страница 16: ...w status alarm and to simplify adjustments To adjust the burner for optimal burning a number of parameters can be changed via the control unit Its functions are as follows When pressing A or B the dis...

Страница 17: ...ed 40 Display slide 5 Matn pellets Pellet feeding Min Minimum Time of duration for feed screw at minimum power 2 5 Max Maximum Time of duration for feed screw at maximum power 5 0 Display slide 6 Fl k...

Страница 18: ...hen the furnace has reached its temperature or when the eternal plug is disconnected Activating Deactivating of the accumulator control position is done by simultaneously pressing and OK When the accu...

Страница 19: ...eengaged Putting the Control Unit in Operation Before the control unit is connected all cables must be connected in a satisfactory way Ensure the temperature sensor is set up in a thermostat tube in t...

Страница 20: ...UR RESPONSIBILITY 20 Adjustment is done by carefully turning the small potentiometer located on the temperature transductor card in the control unit until correct temperature is shown in the display c...

Страница 21: ...power position but turns off and alarms before turning into high power position Not enough time duration on the value Wait The burner turns off due to the overheating protection on the furnace The va...

Страница 22: ...e protection cover from the burner by loosening the wing nut on the top and the two bolts on the sides Then take a thin screwdriver and loosen the igniter cables from the board Now loosen the two wing...

Страница 23: ...ILITY 23 4 Photo resistor in burner detects a correct ignition 5 Door contact breaker placed on the left side of the burner switches the electricity supply to burner and and feed screw off if the burn...

Страница 24: ...too warm the protection will work as an emergency stop device to the burner The overheating protection can only be rese manually F N 230VAC 24VDC T3 15A bakbrandsvakt bygel i s kringsh llare luckbryta...

Страница 25: ...te that the thermostat is to be potential free that is stress free For the burner to be able to start the furnace temperature must be within pre set temperatures and the thermostat in the in the accum...

Страница 26: ...ection can only be reset manually Note that the thermostats overheating protection and operating thermostat must be potential free that is stress free Also note that the clamp in the fuse holder must...

Страница 27: ...er tube mm 200 Weight kg 9 Pellet Recommendation Diameter mm 6 8 Maximum Length mm 32 Eurofire pellet burner with associated control and feed system is CE marked and is manufactured in accordance with...

Страница 28: ...heating for closed installation system 4 without water exchanger in this version You can install boiler in opened installation systems To get 3 years guarantee heating system should be equipped in 4 w...

Страница 29: ...and return to water exchanger built in the boiler There are 2 pipes form side of the boiler for connection It is very important that You will use special valve to realase water supply when temperature...

Страница 30: ..._________________________________City __________________________________________________ Contact Person __________________________________________________________________________________ Telephone ___...

Страница 31: ...rrent User s Manual Customer was trained and is familiar with boiler s operating and maintenance as well as with the safety rules Date of installation First start up Service company signature and stam...

Страница 32: ...onsk Typen FUTURA Fabrikatsnummern ab 2400 1 Ubereinstimmen mit den Bestimmungen der Niderspannungsgerateverordnung 1995 NspGV 1995 BGBI Nr 19 95 und damit mit der durch sie umgesetzten Niderspannungr...