3 - DESCRIPTION OF THE UNIT (FIG. 1)
The
COMFORT LINE™
(CFL) unit that you have just purchased is part of a range of comfort units with high available
static pressure. It is used for heating, cooling, dehumidification and air filtration. It includes a coil with one or two
hot water or cold water supply circuits and may include an electrical heater for heating.
a - Fan motor assembly access panel and filter
b - Filter runner except for size 0
c - Supply air collars
d - Header couplings
e - Coil lower access panel
f - Exchanger coil
g - Air bleed and drain valves
h - Fan motor assembly
i - Electrics box
j - Condensate drain pan
k - Condensate drain pump
l - Condensate drainage
m - Oblong mounting hole Ø12 x 30 mm
n - Air filter
o - Fresh air inlet knockout (opposite side to electrics
box)
p - Resilient mount
q - Return air grille
3.1 -
Name plate (Fig.2)
The name plate contains all the information required to identify the unit and its configuration. This plate is placed
on the technical side that has all the connections, above the fresh air inlet.
Before contacting us, please note the serial no. and the designation.
B
Code
C
Serial number
D
Unit designation
E
Rated motor power
F
Motor rotation speed
G
Coil type
H
Wiring diagram reference
I
Motor speed wiring
J
Maximum operating pressure
K
Electric heater specifications (if fitted)
L
EC declaration number
This device may be used by children aged eight and over, and by persons with limited physical,
sensory or mental capabilities, or by persons with insufficient experience or knowledge, provided
that they are being correctly supervised or provided they have received instructions on how to
use the device in complete safety, ensuring that they have a full understanding of any risks
involved. Children must not play with the unit. User cleaning and maintenance must not be
performed by children.
During normal use, this unit is intended to operate under the following conditions:
■
Maximum altitude: 2000 m,
■
Minimum and maximum storage temperatures: -20 °C/+65 °C,
■
Minimum and maximum operating temperatures: 0 °C/+ 40 °C,
■
Indoor return air maximum humidity level: 27°C DB (dry bulb) at 65% RH (Relative Humidity),
■
Clean interior environment (no corrosive substances present).
The device is designed for indoor use, and requires protection from any form of impact. Protection
rating IP 20 IK02.
This device is designed to operate in an over-voltage category II and pollution degree 2 environment,
in accordance with IEC standard 664-1.
To ensure a pollution degree 2 environment, the device must be protected from water and oil
splashes, and the dust allowed to settle on it must be limited.
COMFORT LINE
TM
EN-18
Содержание COMFORT LINE
Страница 1: ...COMFORT LINE TM 06 2022 EN7533229 03 Instruction manual...
Страница 3: ...Fig 1 b a e j i p f o h n m c g i d k n q III COMFORT LINETM...
Страница 5: ...Fig 4 Fig 5 a b a c V COMFORT LINETM...
Страница 7: ...Fig 10 Fig 9 a b VII COMFORT LINETM...
Страница 8: ...Fig 12 Fig 11 a d e b c COMFORT LINETM VIII...
Страница 9: ...i k b a a d d f g j i Fig 13 c e h h IX COMFORT LINETM...
Страница 10: ...Fig 14 b a c c d d e f COMFORT LINETM X...
Страница 11: ...Fig 15 a b b c d d e XI COMFORT LINETM...
Страница 12: ...Fig 16 Fig 17 e f b e h g COMFORT LINETM XII...
Страница 13: ...Fig 18 a a b XIII COMFORT LINETM...