6.2 Functional Characteristics
1 Analysis
Modulation
channel
frequency processing (16 channels)
2
Analysis Absolute received signal value processing, To guarantee the S/N optimal value (Low level
signal).
3
Analysis Absolute received signal value processing, for fault detection, behaviour deterioration,
masking.
4
Analysis Signal trend to select various cases of AGC behaviour..
5
Analysis DC Power supply voltage processing (battery charger), High or Low.
6
Analysis AC Power supply voltage processing, Presence or Absence.
7
Analysis Tampering of Tx and Rx heads.
8
Availability Stand-by input control, for monitor adjustment and historical inhibition, living always active
the alarm status generation.
9 Availability Test input control, to procure on receiver the alarm relay activation in case of positive
result.
10 Activation Three static relay output for alarm, tamper, fault on receiver and transmitter.
11 Activation Three signalling LED for alarm, tamper, fault on receiver and transmitter
12 Activation Synchronism signal output of transmitter for the other transmitters synchronization
13 Activation Synchronism signal input on transmitter for the local transmitter synchronization
14 Availability Output terminal block for the battery 12 V/2 Ah connection in case of mains absence.
15 Availability 16 positions switch for modulation channel frequency choice. During the installation phase
the receiver identifies and store automatically which channel must be used during
working phase.
16 Availability On the receiver of an acoustic system for the electronic alignment, acquisition of the
alignment values, quality of the alignment, and walk test, without any other external
instrument
17 Availability On the transmitter also on the receiver there’s one connector to measurement.