CIAS Elettronica S.r.l.
Ed 2.0
Installation Handbook
page
27
to
44
ERMUSA
2.6 Length of the Dead Zones near the equipment
The length of the dead zones near the equipment is based on the distance of the equipment
from ground, on the sensitivity set on the receiver (figure 8).
With regard to the considerations stated above, and based on plant requirements, the
equipment must be installed at a certain height from ground.
In mean plant the height must
be 85 cm. (from the ground and the centre of the equipment).
If the barriers are installed on a wall (fig. 3), the min. suggested distance from the max.
overhang and the centre beam is 30 cm.
20
30
10
40
50
60
70
80
90
100
20
30
10
40
50
60
70
80
90
100
1
2
3
4
5
6
7
8
9
10
Antenna
centre height
from ground [cm]
Dead Zone
lenght [m]
Maximum
sensitivity
Minimum
sensitivity
Figure 9 : Dead zone length near the equipment versus installation height. From the ground
and the centre of the equipment
The next figure shows the corner crossing overlap between sections.
Содержание ERMUSA 30
Страница 43: ...NOTE...